YG12F_Ope_E.pdf - 第96页
2-38 2 asic operation 3 Click the icon of the feeder you w ant to oper ate. Click the icon of the feeder plate number , at which the tape feeder you want to operate is installed, in the feeder list in lower part of the…

2-37
2
asic operation
5.2 Operation check
n
Checking the tape feeder operation
Check if operation is correct after setting the tape feeder on the mounter.
1
Open the feeder screen.
Press the [Unit] button and then select the [Feeder] tab to open the feeder screen.
Feeder screen
24225-M7-00
2
Select the feeder.
Click the feeder plate number section or use cursor buttons in upper part of the screen to select a
number of the feeder plate where the tape feeder you want to operate is installed.
Feeder screen
Selecting the feeder
24226-M7-00

2-38
2
asic operation
3
Click the icon of the feeder you want to operate.
Click the icon of the feeder plate number, at which the tape feeder you want to operate is installed, in
the feeder list in lower part of the screen. The air supply is switched on or off each time you click this
button.
Click several times to operate the feeder and check for any malfunctions.
Feeder screen
Selecting the feeder
24227-M7-00
26
27
28
29
35
32
33
32
34
40
36
37
38
39
41
42
43
44
23
24
25
26
27
28
29
30
31
42
43
45
46
47
48
49
Plate numbers
Feeder plate number
Feeder plate number
23216-M7-00

2-39
2
asic operation
n
Checking the tray changer operation
1
Open the tray changer screen.
Press the [Unit] button and then select the [Auto TC] tab to open the tray changer screen.
2
Extract a pallet from the tray changer.
Press the [Pallet Set] button to check whether a pallet is correctly extracted from the tray changer.
Tray changer screen
Selecting a pallet
[Pallet Set]
button
Enter a pallet number
24228-M7-00