Specification_SIPLACE_S23HM_eng.pdf - 第34页
33 Technical Data: Connections Pressure Supply Power Supply: 3 m Cable with CEKON-Connector 3 x 16A 230 Inner Edge Fixed Side of Transport LAN Supply Signal In terface PCB Conveyor Connectio ns and Energy Required Mains …

32
Detail documentation of the PCB
transport interface is available from
Siemens AG.
Technical Data:
Signal Interfaces
Conveyor 1 is Off Conveyor 2 is On
Conveyor 1 is Off Conveyor 2 is On
Conveyor 1 is On Conveyor 2 is On
Transport Direction
Transport Direction
Conveyor Section 1
PCB
Sensor
Conveyor Section 2
Station n Station n+1
has just received
the PCB
Requirement
Delivery
Permission
Receival
Requirement
Delivery
Permission
Receival
Transport Direction
Conveyor Section 1
PCB
Sensor
Conveyor Section 2
Station n
has just
delivered PCB
Station n+1
waits for PCB from
station n, but has
not received it
Requirement
Delivery
Permission
Receival
Requirement
Delivery
Permission
Receival
PCB
Sensor
Conveyor Section 1
Conveyor Section 2
Station n
delivers PCB
to station n+1
Station n+1
waits for PCB
from station n
Requirement
Delivery
Permission
Receival
Requirement
Delivery
Permission
Receival
PCB
Sensor
2. PCB handling has started
3. PCB is at delivery
4. PCB transport is finished

33
Technical Data:
Connections
Pressure Supply
Power Supply:
3 m Cable with
CEKON-Connector 3 x 16A
230 Inner Edge
Fixed Side of Transport
LAN Supply
Signal Interface
PCB Conveyor
Connections and Energy Required
Mains voltage requirement
230/400 V∼ / 119/208 V∼
± 5%, 50/60 Hz
Total connected load 5 kVA
Gross output 5 kW
Fuses 3 x 16 A
Power outage max. 20 ms
Compressed air requirements min. 5.5 bar, 250 Nl/min
Compressed Air Specification
Particles: max. particle size by density,
based on ISO/DIS 8573-1 Class
Particle size
Particle density
0.1 µm
0.1 mg/m³
Dew:
Pressure dewpoint
Dewpoint
Class 4
+ 3° C
Oil:
max. oil content
Particle density
Class 1
0.01 mg/m³

34
Technical Data:
Dimensions and Set-Up Conditions
Values
Length 1587 mm
Width 2425 mm
Height with warning lamp 1836 mm
Weight of basic model 1500 kg
Weight fully equipped 2000 kg
Permissible surface load
sub-floor
> 1 metric ton/m² (weight when fully
equipped / erection area x safety margin)
Permissible environmental
influences:
Room temperature
Humidity
Between 15° and 35°C
30-75%, on average not higher than 45%,
so that no condensation can ever form on
the machine
Maximum noise generation 74 dB
A
252
375
Height of PCB transport
830 ± 15 mm (standard)
900 ± 15 mm (option)
930 ± 15 mm (option)
950 ± 15 mm (option)
SMEMA
Foot height 120 mm
SIPLACE S-23 HM
1836
1036
1587
300
740
1921
2425
All Units in mm