Chapter3_Repair_Guide.pdf - 第310页

Model DECAN Series Company SAMSUNG TECHWIN Module 3.18 V ACUUM DEVICE V ersion 01 Tit le 气缸速度检查 Page 3-18-2 Note [ 气缸速度检查 ] 1. 在 MMI 菜单,将使用权 限切换为 Service 阶段 2. 在 MMI 菜单,选择 <Diagnosis> → <F2(I/O)> → <Cylind…

100%1 / 357
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.18 VACUUM DEVICE
Total Pages
18
目录
[气缸速度检查] ..................................................................................................... 2
[IO 检查] ............................................................................................................... 3
[检查 MAIN AIR BLOW REGULATOR] ............................................................ 4
[组装 FRONT SOL ASSY SUB] ........................................................................... 5
[组装 REAR SOL ASSY SUB] .............................................................................. 7
[检查 VACUUM PUMP 及气动量] ......................................................................... 9
[更换 MAIN AIR REGULATOR] ......................................................................... 10
[设定主气动] ....................................................................................................... 11
[连接 MAIN MANIFOLD 气动软管] ..................................................................... 12
[更换 MAIN AIR FILTER] ................................................................................... 14
[更换 VACUUM PUMP] ...................................................................................... 15
[更换 VACUUM PUMP(OPTION)] ...................................................................... 17
[检查 SOLENOIDE VALVE] ............................................................................... 18
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.18 VACUUM DEVICE
Version
01
Title
气缸速度检查
Page
3-18-2
Note
[气缸速度检查]
1. MMI 菜单,将使用权限切换为 Service 阶段
2. MMI 菜单,选择<Diagnosis><F2(I/O)><Cylinder Check>
3. 执行<Automatic>后,确认各项目的气缸启动速
4. 参考标准值,检查是否正常启动
NO.
项目 检查标准
1 PLACE STOPPER #1 UP 100 ~ 130ms
2 PLACE STOPPER #1 DOWN 100 ~ 130ms
3 BACKUP TABLE #1 UP 310 ~ 330ms
4 BACKUP TABLE #1 DOWN 70 ~ 120ms
5 PLACE STOPPER #2 UP 80 ~ 110ms
6 PLACE STOPPER #2 DOWN 80 ~ 110ms
7 BACKUP TABLE #2 UP 310 ~ 330ms
8 BACKUP TABLE #2 DOWN 70 ~ 120ms
9 ANC SHUTTER #1 CLOSE 50 ~ 70ms
10 ANC SHUTTER #1 OPEN 40 ~ 50ms
11 ANC SHUTTER #2 CLOSE 50 ~ 70ms
12 ANC SHUTTER #2 OPEN 40 ~ 50ms
*Backup Table /下移动时,不应产生摩擦音、干扰音
Model
DECAN Series
Company
SAMSUNG TECHWIN
Module
3.18 VACUUM DEVICE
Version
01
Title
IO检查
Page
3-18-3
Note
[IO 检查]
1. 通过 I/O 画面,确认<Diagnosis><F2(I/O)>画面上表示的输入相关部位上传感器或其他信号是否
正常启动
2. 按照输出相关信号,确认是否正常启动
3. 按下前/后面选择开关按钮,确认是否切换前/后面,还确认前/后面送料器变更功能是否正常工作
4. 确认是否启动送料器浮起传感器
5. 依次将 Feeder Origin 具插入到 1, 30, 59 Feeder Slot 后,确认传感器是否启动
6. 按照标准,检查是否正常启动
发送/接受 I/O 信号时,应正常启动
Input Sensor (Entry PCB #1/#2, Front/Rear PCB #1/#2, Exit PCB #1/#2/#3)应正常启动
应前/后面选择开关切换及送料器变更功能正常启动
应正常启动前/后面送料器浮起传感器