E dition 1 .0 IPS Adjustment for V arious H ead T ypes on the Module < H24 head > FK - 9F50 - 74 -0E 1-1 FUJI C ORPORA TION Chapter 1- H24 head IPS adjust ment IPS Camera Pos ition Adjus tment, Curre nt Val ue (Gra…

CONFIDENTIAL

Edition 1.0 IPS Adjustment for Various Head Types on the Module
<H24 head>
FK-9F50-74-0E 1-1 FUJI CORPORATION
Chapter 1- H24 head IPS adjustment
IPS Camera Position Adjustment, Current Value
(Grayscale Value) Adjustment and Area Check on the
Machine
Requir e d Jigs
Drawing No.
Name
Qty
Photo
2AGKNJ001500
H24 IPS cam er a
resolution
measurement jig
2
2AGTHJ004802
IPS Monitor Jig
1
Required softw ar e
Name
Drawing No.
Notes
MotionAdjustmentTool
None
Inst al l fro m the NXT application C D-ROM
Inspection item
Tolerance
LED current adjustm ent
Grayscale value GR = 120~160, GL =120~160 (adjust current
value so GR & GL gray scale
values are greater than 95 & less
than 250. Target: 120
CURRENT value: 24 m A or less
Camera resolution
check
L: X = 92~108
L: Z = 92~108
Center val ue
R: Xs = 380~400
(Target: 390) , Zp = 235~255 (Target: 245)
L: Xp = 80~100
(Target: 90
)
, Zp = 237~253 (Target: 245)
Tilt
R: dX = 0~6 (Target: 0), dZ = 0~9 (Target: 0)
L: dX = 0~6
(Target: 0), dZ = 0~9 (Target: 0)
CONFIDENTIAL

Edition 1.0 IPS Adjustment for Various Head Types on the Module
<H24 head>
FK-9F50-74-0E 1-2 FUJI CORPORATION
Preparation on the module
1. Remove the covers.
2. Attach the jigs (2AGKNJ001500*) to holders B and X on t he head.
3. To adjust the IPS camera position, it is necessary to move the R-axis to the MT reset
position. The procedure is explained below.
4. Attach the head to t he module and t ur n t he base pow er O N.
5. After the machine wakes up, push the start button and then push the cycle stop button
immediately. After that, check that the R-axis h as been moved to the MT reset position.
6. Check the servo count er on the modu le using the Motion Adjust ment Tool.
7. Startup MotionAjustmentTool.
8. Enter the IP address of the base and t he module number, and then click [Connect].
CONFIDENTIAL