Panel Operations 4-3 <Stop> and <Reset> switch.  Front/Rear select switch, Front/Rear panel lamp(Optional) It is the switch that determines which one of t he front operation panel and rear operation panel wi…

100%1 / 109
Samsung Component Placer CP45FV Series Introduction
supply power to the power systems such as a motor. To cut off the power supply,
press the red switch.
Safeguard override key switch (Front / Rear)
This is used for the door interlock bypass. It is used limitedly only when performing
initial setting or maintenance of the equipment.
Warning
The safeguard override key switch must be used by the
designated responsible personnel. It must be carefully
used for machine operation.
<Ready> button
This is a switch for initiating the operation of this machine. The power is supplied to
the driving systems such as motor. It is used to put the machine into the standby
status after power-up. <EMG (emergency stop)> switch can be pressed to release the
standby state.
<Start> button
This is a switch for initiating the operation of this machine. Automatic operation is
initiated if this switch is pressed.
This switch can be activated for the following cases..
Temporary stop status of operation by <Stop> switch during automatic operation
Error stop status that can be restarted
Warning
Pressing the Start switch without checking the presence
of worker nearby could cause injury. Be sure to check if
there is any worker near the machine before pressing the
Start switch.
<Stop> button
This is a switch for temporary stopping of the operation. Automatic operation of this
machine is temporarily stopped if this switch is pressed. If this switch is pressed
while the placement is in progress, the operation is stopped after the present operation
is completed. This switch can also be used for turning off alarm sound due to an error.
<Reset> button
This is a switch for terminating the operation of this machine. Automatic operation of
this machine is forcefully terminated if this switch is pressed. This switch is used for
deactivating either temporary stop status that had been activated by pressing the
<Stop> switch or the stop status due to an error. The <Reset> switch cannot be
activated during automatic operation of this machine.
<Feeder change> button
When this switch is pressed, the XY gantry moves to a safe position so that the feeder
can be replaced.
EMG (Emergency Stop) switch
This is an emergency stop switch. Operation of this machine is immediately
suspended if this switch is pressed in case of an emergency. Supply of all powers
except for the power to a computer is ceased. The emergency stop status can be
released by turning the <EMG> switch in the direction of the arrow and pressing the
4-2
Panel Operations
4-3
<Stop> and <Reset> switch.
Front/Rear select switch, Front/Rear panel lamp(Optional)
It is the switch that determines which one of the front operation panel and rear
operation panel will have the control authority. Whether or not the corresponding
operation panel has the control authority depends on the status of this switch. (Start,
Feeder change, Keyboard, Mouse). The control authority according to the switch
status is as shown on the following table.
The front
panel select
switch status
The rear
panel select
switch status
Front lamp
status
Rear lamp
status
Control Authority
OFF OFF OFF OFF None
ON OFF ON OFF Front Operation Panel
OFF ON OFF ON Rear Operation Panel
ON ON BLINK BLINK None
4.2. Standards for Lighting Signal Light
This machine comes with a signal light for indicating the present status of the machine.
The signal light indicates the following;
Lighting of a red lamp
Indicates the stop status through self-diagnosis of the system. Warning sounds ring
continuously and messages are indicated as the red lamp is lighted.
Flashing of a red lamp
Indicates either the pressing of the <EMG> switch or the emergency stop status
through self-diagnosis of the system. Warning sounds ring continuously and
messages are indicated as the red lamp is flashed.
Lighting of a yellow(or blue) lamp
Indicates the standby status of operation.
Flashing of a yellow(or blue) lamp
Indicates either component shortage in the tray feeder or adsorption error. Warning
sounds ring continuously and messages are indicated as the yellow(or blue) lamp is
flashed.
Lighting of a green lamp
Indicates that this machine is currently being operated automatically.
Flashing of a green lamp
Indicates temporary stop status. Automatic operation can be resumed by pressing the
<Start> switch.
Samsung Component Placer CP45FV Series Introduction
Red
Yellow
(Or Blue)
Green
Figure 4-2. Signal Light
4.3. Button Manipulation of Teaching Box
Used for manipulating and homing the head as well as teaching the component pick-up
and placement point. The teaching box has a switch selecting the items to teach, X-Y
adjustment button, Z-axis Up/Down button, rotating motion button, etc. These switches
and buttons are arranged in the teaching box separately and the teaching box has an LED
indicating the buttons currently in use.
A teaching box also can be used only when the yellow lamp in the signal light. The
buttons on the teaching box are explained below.
Figure 4-3. Teaching Box
4-4