Introduction(CP45FV) Eng.pdf - 第64页

Samsung Component Placer CP45FV Series Intr oduction 5.2. Feeder Unlock Sensor Feeder unlock sensors are installed at the fr ont and rear of this machine. The system comes into the emergency stop status if the feed er is…

100%1 / 109
Sensor Functions
Chapter 5. Sensor Functions
5-1
5.1. Door Switch
Door switches for detecting the opening/closing status of the front and rear doors are
attached to this machine respectively.
Figure 5-1. Door Switch
If the door is open while this machine is running, the door switch is activated and the
system comes into the emergency stop status. The emergency stop status is released if the
door is closed. In order to resume the operation, press <Stop> and <Reset> switch on the
operation panel to release the emergency status, then press <Main Start> and <Ready>
switch.
Warning
If the safety sensor of the door is cancelled arbitrarily, the
machine will not stop even though the door is opened
during operation, which could cause injury.
The safety sensor of the door must not be cancelled
arbitrarily.
Samsung Component Placer CP45FV Series Introduction
5.2. Feeder Unlock Sensor
Feeder unlock sensors are installed at the front and rear of this machine. The system
comes into the emergency stop status if the feeder is not installed correctly at the feeder
base. In this case, verify that the feeder is installed properly.
Front Feeder Unlock Sensor (Ligh
t
receiving section)
Front Feeder Unlock Sensor (Ligh
t
emitting section)
Rear Feeder Unlock Sensor (Ligh
t
emitting section)
Rear Feeder Unlock Sensor (Ligh
t
receiving section)
Caution
If the feeder loose sensor is cancelled arbitrarily, the head
and the feeder might collide as a loose feeder cannot be
sensed.
Do not cancel the feeder loose sensor arbitrarily.
5-2
Sensor Functions
5-3
5.3. Board Detection Sensor
There are five board detection sensors installed on the PCB take-in and take-out paths of
the conveyor.
Input Sensor
Wait Sensor
Place Sensor
Quick Load Sensor
Output Sensor
Figure 5-2. Installing Position of PCB Detection Sensors
The positions and functions of each sensor are as follows.
Input Sensor: Detects take-in of PCB into this machine from the previous process.
Wait Sensor: Detects PCB in the Wait buffer (at the wait position).
Place Sensor: Detects PCB in the place buffer (at the placement position).
Quick-Load Sensor: Detects PCB completed placement so that the PCB in the wait
buffer can be loaded quickly.
Output Sensor: Detects PCB taken out from the machine.
The conditions for detection may vary depending on the installation method, distance,
and angle and location of each sensor as well as due to dust, external light, shape, and
color of the board. Therefore, sensitivity of a sensor should be adjusted by using the
actual board that will be used. When adjusting the sensitivity of the board detecting
sensor, if there is no PCB, neither the red nor the green LEDs shall be turned on. The
“lightness/darkness“ adjusting screw shall always be turned to the “L” side.
If there is a PCB, turn the sensitivity adjusting screw clockwise so that both the red and
green LEDs are turned on.
If the “lightness/darkness“ adjusting screw is not turned to the “L” side, only the red LED
is turned on.
For reference, the sensitivity of the input sensor, quick load sensor and output sensor
cannot be adjusted.