Introduction(CP45FV) Eng.pdf - 第96页

Samsung Component Placer CP45FV Series Intr oduction PCB #2 PCB #1      Adjust the machine level until there is no bl ocking sound at the gap between machines while pushing the PCB slowly . PCB #1 PCB #2 In the case…

100%1 / 109
Transfer & Installation Procedure
7-5
Level
Figure 7-4. Machine level adjustment – using the spanner supplied with the machine
15. Adjust the level placing the level on the top surface of the feeder base and Y1 axis
L/M guide. The accuracy of the level gauge shall be 0.02mm/m, and its tolerance
shall be less than 0.05mm/m.
16. The foot of the machine must be supported on the floor with even supporting force.
To achieve this, the locking pressure of the nuts of the leg shall be adjusted so that
equal force may be applied to the legs. Check if there is any nut loosely tightened.
After level adjustment is completed, tighten the nuts securely.
Caution
Unless the machine is level, the accuracy of the machine
will be affected. Ensure that the machine is level and check
if the legs of the machine are tightened securely.
The procedure for adjusting the level of the machine is given below.
After moving the new machine near to the existing one, lower the legs of the machine
so that it is aligned level with the existing machine. Then adjust the level keeping the
level difference below 0.1mm/m.
Using a lever, move the machine to the position where the gap between the existing
machine and the edge of the conveyor can be kept between 3~5mm.
Put the PCBs on each conveyor of the two machines, and set the machines so that the
level difference is 0.05~0.1mm, enough to allow the PCBs to move downward.
Essentially, the slope of the conveyor shall be set to allow for the “Downflow” of the
PCB in the direction in which the PCB is moving. To ensure the straight movement of
the PCB between machines, the machines must be installed correctly so that there
will be no unparallel gap at either front or rear side of the PCB, when the PCB is
tightly contacted to the reference line.
Samsung Component Placer CP45FV Series Introduction
PCB #2
PCB #1
Adjust the machine level until there is no blocking sound at the gap between
machines while pushing the PCB slowly.
PCB #1 PCB #2
In the case of level adjustment between two machines, it is difficult to set the level of
the second machine so that its tolerance can be maintained to be less than 0.05 mm/m
because its conveyor cannot be leveled. Therefore, adjust the level of the machine so
that the level tolerance can be maintained to be less than 0.05 mm/m in the left and
right side direction of the PCB (PCB flow direction), and less than 0.1 mm/m in the
front and rear side direction of the PCB.
When adjusting the level of the machine legs, it is recommended to adjust the level in
one direction at a time by combining two legs into one set as per the following
Figure)
Level in the front and rear direction: Adjust the level of the front and rear legs in
pairs.
Level in the left and right direction: Adjust the level of the left and right legs in
pairs.
Adjust the legs in pairs
Direction of the level
Front and rear side
adjustment
Right and left side
adjustment
Figure 7-5. Adjusting the level between two machines
17. Install supports for the monitors and mount them on the top of the machine.
Assemble the connector inside of the machine and install two monitors (when
assembling, tighten the bolts completely)
18. Install the signal light with 4 bolts to the left of the top surface, and connect the lamp
7-6
Transfer & Installation Procedure
7-7
with the connector at the left of the inside of the machine.
19. Following level adjustment, connect the keyboard and mouse to the top of the front
cover and install the teaching box at the bottom right of the front panel.
Figure 7-6. Installing the monitors and signal light
20. Ensure that the machine power supply has been correctly connected to suit the use of
the machine.
Reference
Rating: Single phase, 60Hz, 220 Volt, voltage variation ± 5% (10Volt).
Power consumption: CP40(2.6 KVA), CP45(2.6 KVA)
Grounding: Based on 3
rd
class grounding, the Mega Test value shall be less than 100
Ω between the ground wire and the machine.
AVR: The AVR is a basic option. It is recommended to have the capacity margin at
more than 20%.
Caution
When taking a single phase power from a 3 phase power
source, any incidental trip of power may cause phase
distortion, which may lead to damage of the machine. To
avoid such an occurrence, total use of single phase power
is recommended to be less than 40% of the total capacity
(Kw).
21. Insert the power supply cable into the AC power input terminal. At this time, the
power should not be turned on.