SOKO 2 Retrofit instructions SOKO Small Traceability ASUS (S TA ) on the basis of station software version 505.03 SP 1 11/2005 Edition 33 2 2 2 2 2 [HKEY_LOCAL_MACHINE\SOFTW ARE\Sieme ns SIPLACE\T rac eability\ST A\Msg] …

2 Retrofit instructions SOKO Small Traceability ASUS (STA) on the basis of station software version 505.03 SP 1 SOKO
11/2005 Edition
32
2
[HKEY_LOCAL_MACHINE\SOFTWARE\Siemens SIPLACE\Traceability\STA\BcName] 2
[HKEY_LOCAL_MACHINE\SOFTWARE\Siemens SIPLACE\Traceability\STA\Bc
Name\1] 2
2
[HKEY_LOCAL_MACHINE\SOFTWARE\Siemens SIPLACE\Traceability\STA\DB] 2
"DlgTimeOut"=dword:00000028
The value specifies the maximum time in seconds a query to the database is permitted
to take. The time is specified as a hexadecimal value. If this value is exceeded, a timeout
message is issued.
"NoPrefix"=dword:00000001
Values: 0 or 1 ( 0 = inactive, 1 = active, default =1)
When active, the barcodes are passed to the SMV interface without prefixes.
"NoActivate"=dword:00000001
Values: 0 or 1 ( 0 = inactive, 1 = active, default = 1)
When active, barcode scans with the same ReelId, which correspond to activating the
track, are not passed to the SMV interface. It only makes sense to deactivate this property
if the "NoScan" parameter (see below) is not active.
"BcName"="ReelId"
This is the name of the first barcode field in the component verification dialog box.
"DBConDriver"="SQL Server"
"DBConServer"=""
DBConServer = ServerName
“DBConDatabase”=””
DBConDatabase = DatabaseName
"DBConUid"=""
DBConUid = UserId
"DBConPwd"=""
DBConPwd = Password
"DBDNS"=""
DBDNS = Microsoft-compliant connection specification, takes precedence if set.
"DBUpdateCount"=dword:00000030
Values 0 through x (0 = container sizes not updated, or container size is updated in the
database after X PCBs)
"DBUpdateWithSetup"=dword:00000001
Values: 0 or 1 ( 0 = inactive, 1 = active)
When active, the filling levels of the previous setup are updated in the database with
each new job. For example the DBUpdateCount is 30 PCBs and 29 boards are produced
and the job changes the levels are updated in the database although the number of
pcbs are not reached.

SOKO 2 Retrofit instructions SOKO Small Traceability ASUS (STA) on the basis of station software version 505.03 SP 1
11/2005 Edition
33
2
2
2
2
2
[HKEY_LOCAL_MACHINE\SOFTWARE\Siemens SIPLACE\Traceability\STA\Msg] 2
2
[HKEY_LOCAL_MACHINE\SOFTWARE\Siemens SIPLACE\Traceability\STA\Msg\0] 2
2
[HKEY_LOCAL_MACHINE\SOFTWARE\Siemens SIPLACE\Traceability\STA\Msg\1] 2
2
2
2
The table names:
“DBTableReel"="REEL"
"DBTableTrace"="TRACE_LOG"
The field names in the “DBTableReel“ table
"DBFieldNameReelIdIn"="RID"
"DBFieldNameQTYIn"="QTY"
"DBFieldNameCompIn"="SPN"
The field names in the "DBTableTrace" table
"DBFieldNameTimeStamp"="TIMESTAMP"
"DBFieldNameQTYOut"="QTY"
"DBFieldNameLoc"="LOC"
"DBFieldNameStation"="TRACE_STATION"
"DBFieldNamePrg"="MPROG"
"DBFieldNameReelIdOut"="RID"
"DBFieldNamePcbId"="PCBID"
This section allows message texts appropriate for the relevant error to be set for each key.
The sequence and number is mandatory and must not be changed.
"Message"="ok"
@="STA_NO_ERROR"
"Message"="no database connection"
@="STA_NO_DB_CONNECTION"

2 Retrofit instructions SOKO Small Traceability ASUS (STA) on the basis of station software version 505.03 SP 1 SOKO
11/2005 Edition
34
[HKEY_LOCAL_MACHINE\SOFTWARE\Siemens SIPLACE\Traceability\STA\Msg\2] 2
2
[HKEY_LOCAL_MACHINE\SOFTWARE\Siemens SIPLACE\Traceability\STA\Msg\3] 2
2
[HKEY_LOCAL_MACHINE\SOFTWARE\Siemens SIPLACE\Traceability\STA\Msg\4] 2
2
[HKEY_LOCAL_MACHINE\SOFTWARE\Siemens SIPLACE\Traceability\STA\Msg\5] 2
2
[HKEY_LOCAL_MACHINE\SOFTWARE\Siemens SIPLACE\Traceability\STA\Msg\6] 2
2
[HKEY_LOCAL_MACHINE\SOFTWARE\Siemens SIPLACE\Traceability\STA\Msg\7] 2
2
[HKEY_LOCAL_MACHINE\SOFTWARE\Siemens SIPLACE\Traceability\TraceClient] 2
2
2
"Message"="database error"
@="STA_DB_ERROR"
"Message"="no data found"
@="STA_NO_DB_DATA_FOUND"
@="STA_WRONG_COMPONENT"
"Message"="wrong component"
"Message"="componentlabel reelId mismatch"
@="STA_WRONG_COMPLABEL"
"Message"="invalid container size"
@="STA_WRONG_SIZE"
"Message"="internal error"
@="STA_INTERNAL_ERROR"
"NoScan"=dword:00000001
Values: 0 or 1 ( 0 = inactive, 1 = active, default =1)
When active, deactivated tracks can be activated by clicking a button in the "Empty tracks" list
even when component verification is active. If activation is not permitted, for example if the filling
level falls too low, the corresponding track is deactivated again.