2 Retrofit instructions SOKO Small Traceability ASUS (STA) on the basis of station software version 505.03 SP 1 SOKO 11/2005 Edition 34 [HKEY_LOCAL_MACHINE\SOFTW ARE\Siemens SIPLACE\T raceabi lity\ST A\Msg\2] 2 2 [HKEY_L…

100%1 / 46
SOKO 2 Retrofit instructions SOKO Small Traceability ASUS (STA) on the basis of station software version 505.03 SP 1
11/2005 Edition
33
2
2
2
2
2
[HKEY_LOCAL_MACHINE\SOFTWARE\Siemens SIPLACE\Traceability\STA\Msg] 2
2
[HKEY_LOCAL_MACHINE\SOFTWARE\Siemens SIPLACE\Traceability\STA\Msg\0] 2
2
[HKEY_LOCAL_MACHINE\SOFTWARE\Siemens SIPLACE\Traceability\STA\Msg\1] 2
2
2
2
The table names:
“DBTableReel"="REEL"
"DBTableTrace"="TRACE_LOG"
The field names in the “DBTableReel“ table
"DBFieldNameReelIdIn"="RID"
"DBFieldNameQTYIn"="QTY"
"DBFieldNameCompIn"="SPN"
The field names in the "DBTableTrace" table
"DBFieldNameTimeStamp"="TIMESTAMP"
"DBFieldNameQTYOut"="QTY"
"DBFieldNameLoc"="LOC"
"DBFieldNameStation"="TRACE_STATION"
"DBFieldNamePrg"="MPROG"
"DBFieldNameReelIdOut"="RID"
"DBFieldNamePcbId"="PCBID"
This section allows message texts appropriate for the relevant error to be set for each key.
The sequence and number is mandatory and must not be changed.
"Message"="ok"
@="STA_NO_ERROR"
"Message"="no database connection"
@="STA_NO_DB_CONNECTION"
2 Retrofit instructions SOKO Small Traceability ASUS (STA) on the basis of station software version 505.03 SP 1 SOKO
11/2005 Edition
34
[HKEY_LOCAL_MACHINE\SOFTWARE\Siemens SIPLACE\Traceability\STA\Msg\2] 2
2
[HKEY_LOCAL_MACHINE\SOFTWARE\Siemens SIPLACE\Traceability\STA\Msg\3] 2
2
[HKEY_LOCAL_MACHINE\SOFTWARE\Siemens SIPLACE\Traceability\STA\Msg\4] 2
2
[HKEY_LOCAL_MACHINE\SOFTWARE\Siemens SIPLACE\Traceability\STA\Msg\5] 2
2
[HKEY_LOCAL_MACHINE\SOFTWARE\Siemens SIPLACE\Traceability\STA\Msg\6] 2
2
[HKEY_LOCAL_MACHINE\SOFTWARE\Siemens SIPLACE\Traceability\STA\Msg\7] 2
2
[HKEY_LOCAL_MACHINE\SOFTWARE\Siemens SIPLACE\Traceability\TraceClient] 2
2
2
"Message"="database error"
@="STA_DB_ERROR"
"Message"="no data found"
@="STA_NO_DB_DATA_FOUND"
@="STA_WRONG_COMPONENT"
"Message"="wrong component"
"Message"="componentlabel reelId mismatch"
@="STA_WRONG_COMPLABEL"
"Message"="invalid container size"
@="STA_WRONG_SIZE"
"Message"="internal error"
@="STA_INTERNAL_ERROR"
"NoScan"=dword:00000001
Values: 0 or 1 ( 0 = inactive, 1 = active, default =1)
When active, deactivated tracks can be activated by clicking a button in the "Empty tracks" list
even when component verification is active. If activation is not permitted, for example if the filling
level falls too low, the corresponding track is deactivated again.
SOKO 2 Retrofit instructions SOKO Small Traceability ASUS (STA) on the basis of station software version 505.03 SP 1
11/2005 Edition
35
2.7.3.2 Configuration for Second Source
The appropriate entries have to be adjusted to the circumstances on each station individually. 2
2
[HKEY_LOCAL_MACHINE\SOFTWARE\Siemens SIPLACE\Traceability\STA\2ndSource] 2
2
Additional scope of services 2
Because the station name is not available on the station when it is connected to SiplacePro, it can
now be written in the registry. 2
[HKEY_LOCAL_MACHINE\SOFTWARE\Siemens SIPLACE\Traceability\STA] 2
The computer name will be used if this entry remains empty. 2
2
"2ndSource"=dword:00000001
2ndSourceAddon 1 = active --> 0 = inactive --> Default is active
"2ndSourcePath"="\\Linecontrol\2ndSource"
Linecontrol is equivalent to the Linecontrol computer name.
Path for the directory on the Linecontrol computer.
This must be adjusted for each station. 2
"2ndSourceFilename"="2ndSource.txt"
File name of the 2ndSource-File --> Can be adjusted.
"2ndSourceSeparator"=" "
Space between 2 component names --> Default is a space
"StationNameReg"=" --> Has to be adjusted for every station.