Operating Parameters B-9 Part 1126931_01 2018 Nordson Corporation Input Setup 30 Input 1 Description: Control options that determine the function of input 1. Value: 0 - Input Disabled 1 – Standby On/Off 2 – Heaters On/…

Operating Parameters
B-8
Part 1126931_01
2018 Nordson Corporation
Standard (contd)
29
Internal Zone Temperature Offset
Description:
The difference in the number of degrees by which the melter's internal
zones will operate. If this parameter is used, the primary internal zone will
operate at a lower temperature than the secondary internal zone as
determined by the value of this parameter.
Value:
0 C to ‐15 C (0 F to ‐30 F)
Resolution:
1 C
1 F
Default Value:
0
Format:
—
Use:
Melter internal zones are designated as follows:
DuraBlue D10/D16: primary=tank; secondary=pump
DuraBlue D4L/D10L/D16L: primary=tank; secondary=pump
AltaBlue TT: primary=tank; secondary=pump
DuraBlue 25/50/100: primary=grid; secondary=reservoir
AltaBlue 15/30/50/100: primary=grid; secondary=reservoir
DuraBlue II Melter: primary=grid; secondary=reservoir
DuraDrum: primary=platen; secondary=pump

Operating Parameters
B-9
Part 1126931_01
2018 Nordson Corporation
Input Setup
30
Input 1
Description:
Control options that determine the function of input 1.
Value:
0 - Input Disabled
1 – Standby On/Off
2 – Heaters On/Off
3 – Motor 1 Enable/Disable
4 – Hose/Applicator 1 Enable/Disable
5 – Hose/Applicator 2 Enable/Disable
6 – Hose/Applicator 3 Enable/Disable
7 – Hose/Applicator 4 Enable/Disable
8 – Hose/Applicator 5 Enable/Disable
9 – Hose/Applicator 6 Enable/Disable
10 – Automatic standby
11 - Motor 2 Enable/Disable
Resolution:
1
Default Value:
10
Format:
Use:
If Motor Enable/Disable (3) is selected, the motor will turn on whenever voltage
is present on the input contacts. To require that the pump key be pressed (pump
enabled) and that there be voltage on the input contacts before the motor can
turn on, set the value of parameter 8, Automatic Pump On to 0 (disabled).
Refer to Installing Melter Inputs in Section 3, Installation, for information about
setting up inputs.
NOTE: Only Input 1 offers control option 10.
Multiple inputs can be set to the same input value. After one or more inputs that
have the same input value are energized, the input functionality will not be
considered inactive (off) until all of the inputs with the same input value are
de‐energized (Multiple inputs set to the same input value are logical ORed.).

Operating Parameters
B-10
Part 1126931_01
2018 Nordson Corporation
Input Setup (contd)
31
Input 2
Description:
Control options that determine the function of input 2.
Value:
0 - Input Disabled
1 – Standby On/Off
2 – Heaters On/Off
3 – Motor 1 Enable/Disable
4 – Hose/Applicator 1 Enable/Disable
5 – Hose/Applicator 2 Enable/Disable
6 – Hose/Applicator 3 Enable/Disable
7 – Hose/Applicator 4 Enable/Disable
8 – Hose/Applicator 5 Enable/Disable
9 – Hose/Applicator 6 Enable/Disable
11 - Motor 2 Enable/Disable
Resolution:
1
Default Value:
1
Format:
—
Use:
If Motor Enable/Disable (3) is selected, the motor will not turn on unless the
pump is enabled and the correct voltage is present on the input contacts.
Refer to Installing Melter Inputs in Section 3, Installation, for information about
setting up inputs.
NOTE: Multiple inputs can be set to the same input value. After one or more
inputs that have the same input value are energized, the input functionality will
not be considered inactive (off) until all of the inputs with the same input value
are de‐energized (Multiple inputs set to the same input value are logical ORed.).
32
Input 3
Description:
Control options that determine the function of input 3.
Value:
0 - Input Disabled
1 – Standby On/Off
2 – Heaters On/Off
3 – Motor 1 Enable/Disable
4 – Hose/Applicator 1 Enable/Disable
5 – Hose/Applicator 2 Enable/Disable
6 – Hose/Applicator 3 Enable/Disable
7 – Hose/Applicator 4 Enable/Disable
8 – Hose/Applicator 5 Enable/Disable
9 – Hose/Applicator 6 Enable/Disable
11 - Motor 2 Enable/Disable
Resolution:
1
Default Value:
2
Format:
—
Use:
If Motor Enable/Disable (3) is selected, the motor will not turn on unless the
pump is enabled and the correct voltage is present on the input contacts.
Refer to Installing Melter Inputs in Section 3, Installation, for information about
setting up inputs.
NOTE: Multiple inputs can be set to the same input value. After one or more
inputs that have the same input value are energized, the input functionality will
not be considered inactive (off) until all of the inputs with the same input value
are de‐energized (Multiple inputs set to the same input value are logical ORed.).