Operating Parameters B-14 Part 1126931_01 2018 Nordson Corporation 50 Current Day Description: Used to set the current day of the week. Value: 1 to 7 (1 = Monday, 2 = Tuesday, etc.) Resolution: 1 Default Value: — Forma…

Operating Parameters
B-13
Part 1126931_01
2018 Nordson Corporation
Seven‐day Clock
Before setting up the clock, refer to Function Keys in Section4, Operation, to
familiarize yourself with the function and use of the clock feature.
If you are unfamiliar with the procedure for accessing and editing operating
parameters, refer to Section 3, Installation, Setting Up the Melter.
To Set the Clock
1. Use parameter 50 to select the current day of the week.
2. Use parameter 51 to set the current time of day.
3. Create schedule 1 by:
a.. Setting parameters 55 and 56 to the time of the day that the heaters
should turn on and off.
b.. Setting parameters 57 and 58 to the time of the day that the melter
should enter and exit the standby mode.
4. Using parameters 60 through 68, create schedules 2 and 3 by repeating
step 3.
5. Use parameters 71 through 77 to assign which of the four schedules
should be used on each day of the week. Up to three schedules may be
assigned each day (to support three work shifts). Each of the eight
control options (0 to 7) that is available in parameters 71 through 77
assigns a different combination of the three schedules. Option 0 is used
hold the melter in the state dictated by the last clock transition until the
next clock transition occurs.
In order for the clock to operate continuously
throughout the week, a valid schedule must be
assigned to every day of the week (parameters
71 through 77).
To prevent unintentional activation of the clock
the default setting for parameters 71 through
77 is schedule 0. which has no time values
assigned to it. With the default set to schedule
0, unintentionally pressing the clock key will
have no affect on the melter.

Operating Parameters
B-14
Part 1126931_01
2018 Nordson Corporation
50 Current Day
Description:
Used to set the current day of the week.
Value:
1 to 7 (1 = Monday, 2 = Tuesday, etc.)
Resolution:
1
Default Value:
—
Format:
—
Use:
Refer to Section 4, Operation, Function Keys, for information about the use and
affects of the seven‐day clock feature.
51 Current Time
Description:
Used to set the local time of the day.
Value:
0000 to 2359 (European time format)
Resolution:
1 minute
Default Value:
(Time set at factory)
Format:
Hours, Hour: Minute, Minute
Use:
This setting only needs to be made once for all daily schedules
55 Schedule 1 Heaters On
Description:
Used to set the time that the clock will turn on the heaters during schedule 1.
Value:
0000 to 2359, ‐ ‐ ‐ ‐
Resolution:
1 minute
Default Value:
0600
Format:
Hours, Hour: Minute, Minute
Use:
Set the desired time for the heaters to turn on.
To disable this parameter, set the parameter's value to “‐ ‐ ‐ ‐” by simultaneously
pressing both of the right‐display scroll keys.
56 Schedule 1 Heaters Off
Description:
Used to set the time that the clock will turn off the heaters during schedule 1.
Value:
0000 to 2359, ‐ ‐ ‐ ‐
Resolution:
1 minute
Default Value:
1700
Format:
Hours, Hour: Minute, Minute
Use:
To disable this parameter, set the parameter's value to “‐ ‐ ‐ ‐” by simultaneously
pressing both of the right‐display scroll keys.

Operating Parameters
B-15
Part 1126931_01
2018 Nordson Corporation
57 Schedule 1 Enter Standby
Description:
Used to set the time that the melter will enter the standby mode during schedule
1.
Value:
0000 to 2359, ‐ ‐ ‐ ‐
Resolution:
1 minute
Default Value:
‐ ‐ ‐ ‐
Format:
Hour, Hour: Minute, Minute
Use:
Set the time that the melter will enter the standby mode during schedule 1.
To disable this parameter, set the parameter's value to “‐ ‐ ‐ ‐” by simultaneously
pressing both of the right‐display scroll keys.
Note: Do not set an enter standby time that is outside of the time period defined
by the schedule's heater on and off time. The melter cannot enter the standby
mode when the heaters are off.
58 Schedule 1 Exit Standby
Description:
Used to set the time that the melter will exit the standby mode during schedule 1.
Value:
0000 to 2359, ‐ ‐ ‐ ‐
Resolution:
1 minute
Default Value:
‐ ‐ ‐ ‐
Format:
Hour, Hour: Minute, Minute
Use:
Set the time that the melter will exit the standby mode during schedule 1.
To disable this parameter, set the parameter's value to “‐ ‐ ‐ ‐” by simultaneously
pressing both of the right‐display scroll keys.
Note: Do not set an exit standby time that is outside of the time period defined
by the schedule's heater on and off time. The melter cannot enter the standby
mode when the heaters are off.
60 Schedule 2 Heaters On
Description:
Used to set the time that the clock will turn on the heaters during schedule 2.
Value:
0000 to 2359, ‐ ‐ ‐ ‐
Resolution:
1 minute
Default Value:
‐ ‐ ‐ ‐
Format:
Hours, Hour: Minute, Minute
Use:
Set the desired time for the heaters to turn on.
To disable this parameter, set the parameter's value to “‐ ‐ ‐ ‐” by simultaneously
pressing both of the right‐display scroll keys.