3123 %1 :\tToolbit not attached The needed toolbit for production is not attached to head or the toolbit file is not correct. - The correct toolbit is not attached - Illegal updated toolbit file - Not correct installed t…

100%1 / 52
3104
%1 :\tInvalid bitbus node in
module configuration file
The configuration file is not
correct. - Illegal update of the configuration file. - Re-install software.
3105
%1 :\tFirmware to download to
controller not found by module Firmware not available. - Installation not executed correctly. - Re-install software.
3106
%1 :\tError found in firmware
during download to controller
Error found in firmware during
download to controller. - Illegal or incorrect firmware file Re-install software.
3107
%1 :\tUsage requested on a not
configured module
The module on which the action is
requested, is not yet configured.
- Mismatch in configuration files.
- Illegal updated files. - Configure module.
3108
%1 :\tUsage requested on a not
calibrated module
The module on which an action is
requested is not yet calibrated. - Not calibrated module. - Calibrate module (exchange calibration).
3109 %1 :\tModule failed to startup The module can not be started. - Hardware or software problems with module.
- Re-configure modules.
- Exchange module.
3110
%1 :\tModule failed to gain the
requested amount of memory Not enough memory available. - Too much programs loaded in memory.
- Temporary solution:
- Configure only the needed modules.
3111
%1 :\tError in action spec: Invalid
fiducial algorithm
The fiducial algorithm defined in
the action spec is not correct. - Illegal action spec.
- Check action spec.
- See action spec documentation.
3112
%1 :\tError in action spec: To
many fiducials for requested
algorithm
A limited number of fiducials can
be applied for correction. - Incorrect action spec. - Verify action spec.
3113
%1 :\tError in action spec: Not
enough fiducials for requested
algorithm
For fiducial correction at least 1, 2
or 3 fiducials are needed (#
depends from algorithm). - Incorrect action spec. - Check action spec.
3114
%1 :\tError in action spec: Invalid
Global fiducial usage
The global fiducial used is not
correct. - Incorrect action spec. - Check action spec.
3115
%1 :\tError in action spec: Not all
fiducials from a matrix measured
with same FA
For proper working of the
machine, all fiducials used within
set (i.. global fiducials)
must be measured with the same
camera. - Incorrect action spec. - Modify action spec.
3116 %1 :\tModule failed to initialize
The indicated module could not be
initialized. - Hardware error. - Remove module from configuration and re-configure.
3117
%1 :\tAction refused by module:
Module in wrong state
The requested action for a module
is not executed. - The module is in a state in which these actions are prohibited. - Retry the action.
3118
%1 :\tAction refused: wrong
module specified
During execution of the action
specification a illegal module was
specified. - Incorrect action spec.
- Check action spec.
- Verify action spec using single step.
3119 %1 :\tAction refused: Invalid data
The data needed to execute the
action is not correct.
- CA-files missing.
- Action spec error.
- Check if the required CA-file is at the aPC.
- Check action spec.
3120
%1 :\tAction refused: No Z
movement allowed in current state
The requested head Z-movement
is not allowed in this machine
state. - Software error. - Retry.
3121
%1 :\tNo communication to
module allowed
Communication to the requested
module is not allowed. - The module can not be used. - Restart the system.
3122
%1 :\tTimeout occurred during
requested action on module
The requested action for a module
is not executed, the module does
not respond within a pre-defined
time window.
- Communication error with module
- Hardware/software of module
- If module is a traytrolley, then it could be that the laser beam (
front/rear) is obstructed.
- Retry if possible.
- Restart the system.
- If module is a traytrolley, then check if all carriers are correct positioned in the
trolley, so that both laser beams (front/rear) are OK.
3123 %1 :\tToolbit not attached
The needed toolbit for production
is not attached to head or the
toolbit file is not correct.
- The correct toolbit is not attached
- Illegal updated toolbit file
- Not correct installed toolbit file
- Attach toolbit to head
- Re-install toolbit file
3124
%1 :\tUnexpected error occurred
in Module
The indicated module could not be
initialized. - Error on module. - Remove module from configuration and re-configure.
3125
%1 :\tController detected error
during action Internal software error. - Retry.
3126 %1 :\tController is in wrong state Internal software error. - Retry.
3127
%1 :\tIncorrect parameter sent to
controller
Control software sent incorrect
data to controller.
- Incorrect action spec (feeder 0 specified).
- Incorrect firmware.
- Check action spec.
- Check firmware version.
3128
%1 :\tThe firmware command is
not yet supported
A command is given to firmware
that is not implemented yet, or is
unknown. - Not documented commands are used. - Use correct commands.
3129 %1 :\tFirmware refused
The firmware specified in the
configuration is not correct. - Illegal update of firmware. - Re-install software.
3130
%1 :\tUnsupported command is
given to the controller
An unsupported command is given
to the controller. - Internal software error. - Report error to your service representative.
3131
%1 :\tController timed out during
action
The controller response is not
within a certain time window.
- Incorrect movement class.
- Incorrect speed mode.
- Check action spec.
- Check package type database.
3132 %1 :\tIncorrect toolbit type in head Unknown toolbit inserted in head. - Unsupported toolbit type inserted in head. - Replace toolbit with correct one.
3133 %1 :\tbitbus node not found The bitbus node is not found. - Module not connected to bitbus. - Check bitbus connection cable.
3134
%1 :\tNot able to disconnect
controllers Not able to disconnect controllers.
- Bitbus error.
- Software error.
- Shutdown system.
- Restart the system.
3135
%1 :\tPosition of servo system
outside limits
One or more servo systems were
attempted to move outside it
physical range or the tolerance on
the nominal position is too large.
- An error in the action spec.
- Calibration error.
- Mechanical adjustment incorrect.
- Check the action spec.
- Calibrate the specific module.
- Re-adjust and calibrate module.
3136 General servo power failure
All conditions for having servo
power are met but there's no servo
power present
( covers are closed,
feedersections are present, no
mains phase failure, no
emergency buttons pressed )
- Servo power not activated ( yet )
- Defective CAN card, defective LIMMS controller or missing
CAN terminator
- Power failure, defective power supply
- Press 'Servo power On' button
- Check aPC errors, see error descriptions in the Service Manual ( contact your
service representative in case of doubts )
- Check leds on LIMMS Power Supply, see Service Manual
- Check fuses, power supply and safety rel
3137
Invalid or inconsistent SBIP entry
parameters
SBIP encountered invalid
parameter values.
- Component id not known by SBIP.
- Component / fiducial file to download not found on APC.
- Illegal component type specified in component description.
- Check component / fiducial file descriptions.
- Report error to your service representative.
3138 Spurious SBIP error encountered
An unidentified error occurred on
the SBIP.
- Retry action.
- Check vision file.
- Shutdown and restart the system.
- Report error to your service representative.
3139
%1 :\tComponent size or angle out
of limits
Component size or angle does not
comply with component
description.
- Wrong description.
- Bad component.
- Adapt component description : check body tolerance and reject level phi
settings.
- Inspect component.
3140
%1 :\tNot enough free space
around fiducial
The interpolation (or 'Synthetic
Edge') algorithm requires a
minimum free space of 40 pixels
around the fiducial
- Board is dirty near the fiducials.
- Bad light conditions.
- Clean fiducial.
- Adapt light setting in fiducial description file.
3141
File access error for verification
log file
In accessing the verification log file
an error has occurred.
- The verification directory on the APC does not exist.
- Disk full.
- An error occurred in the file system.
- Check whether the verification directory on the aPC exist.
- Check the disk space.
- Repeat the verification measurement.
3142
Calibration at rear side cannot be
performed - switch calibration
nozzles
- The requested calibration is only
partly completed.
- Nozzles need to switched to the other machine side.
- This calibration actually requires 4 calibration nozzles for a
fully equipped machine.
- Remove calibration nozzles and mount them on the other machine side.
- Continue with rest of calibration by performing an automatic calibration.
3143 %1 :\tComponent on nozzle
If this message occurs, the
machine tries to calibrate the
vacuum of the nozzle. A
component is on the nozzle so the
nozzle can not be calibrated. - Unexpected component on the nozzle.
- Take component of the nozzle.
- Retry the action.
3144 %1 :\tExternal position error
External
position error
The Y axis detected that the
external encoder input signal from
the X axis was not correct.
- Bad connection of the X encoder signal to the Y axis.
- Defective external encoder input circuit on the Y axis.
- Select retry.
- If the problem keeps re-occurring, see Service Manual.
3145 %1 :\tComponent not measured Error in system call sequence - Bad processing sequence
- Retry action
- Report error to your service representative.
3146 %1 :\tFlux applicator not stopped
Flux applicator did not respond on
STOP/CLAIM command.
- Stop command did not reach flux applicator.
- Acknowledge not received from flux applicator.
- Check wiring.
- Retry the operation.
3147
%1 :\tFirst component lead not
found
The first lead, used as reference,
can not be detected.
- Wrong component attached.
- Wrong component description used.
- Wrong index feeder for tape components.
- Wrong pitch tray for tray components.
- Orientation of the component in feeder not correct.
- Bad contrast
- Verify component and component description in the setup vision menu using
the show definition function, check reject level !
- Check index of the feeder.
- Check the pitch of the tray with the one specified in the action spec.
- Check the orientation
3148 %1 :\tFlux applicator is not rotating
The flux applicator did not start
rotating.
- Start command did not reach flux applicator.
- Acknowledge not received from flux applicator.
- Check wiring.
- Retry operation.
3149
%1 :\tComponent mismatch
(second lead)
Mismatch between the component
description and the measured
component characteristics.
(Second lead).
- Wrong component attached.
- Wrong component description used.
- Wrong pick-up position.
- Verify component and component description by SHOW function.
- Check the pick-up position.