ERR-LIST-ACM.pdf - 第49页

3214 %1 :\tFeedback error lift The lift servo loop is not closed. - Defective cabling to motor or encoder. - Defective motor or encoder. - Defective motor controller. - Defective driver board Check possible causes. 3215 …

100%1 / 52
3203
RETRY
INFORMATION\x0ASection :
%1\x0AFeeder : %2\x0AChannel :
%3\x0AToolbit : %4\x0ANozzle :
%5\x0AVacuum specified :
%6\x0AVacuum measured :
%7\x0AComponent : %8\x0A
3204 The recovery action failed
One or more errors (possible the
same as the original one(s))
occurred during the error recovery
action.
3205
Head: %1\x0ASection:
%2\x0AFeeder: %3\x0AChannel:
%4\x0AComponent:
%5\x0APackage: %6\x0A
3206
RETRY INFORMATION\x0AHead:
%1\x0ASection: %2\x0AFeeder:
%3\x0AChannel:
%4\x0AComponent:
%5\x0APackage: %6\x0A
3207 No active MIS period available
There is no active MIS period, so
the operation cannot be executed.
- The current MIS period is not started yet.
- Inconsistency in internal administration.
- Start production and enter a board.
- Delete current order, start new order and resume production.
3208
Measured: %1 mm.\x0ALower
limit: %2 mm.\x0AUpper limit: %3
mm.\x0A
3209
RETRY
INFORMATION\x0AMeasured:
%1 mm.\x0ALower limit: %2
mm.\x0AUpper limit: %3 mm.\x0A
3210
RVS :\tthis function (%d) has not
been implemented (yet).
A function was activated that has
not been implemented in the
current software version.
- Functions that are not complete yet should not be accessible
for the user.
- By mistake, this function is accessible for the user.
- Clear the error and do not use the functions again.
- Report the error to your service representative.
3211
RVS :\t system communication
error on: %d. A system error occurred. Unknown.
- Retry and continue.
- Restart the system.
- Report error to your service representative.
3212
Component description
incompatible with CA-camera type
The component description is
incompatible with the CA-camera
used.
- The component type is specified for use on only one of the
camera types (LFOV-SFOV) and an attempts is made to use
the component with the other camera type.
- Use the appropriate camera type, or
- Modify the component description.
3213
Error in merging vision data with
action spec data.
Unable to update action spec with
modified vision data. - Not consistent system data.
- Remove order from system.
- If this problem occurs frequently, contact service representative.
3214 %1 :\tFeedback error lift The lift servo loop is not closed.
- Defective cabling to motor or encoder.
- Defective motor or encoder.
- Defective motor controller.
- Defective driver board Check possible causes.
3215 %1 :\tFeedback error puller The puller servo loop is not closed.
- Defective cabling to motor or encoder.
- Defective motor or encoder.
- Defective motor controller.
- Defective driver board. Check possible causes.
3216 %1 :\tFeedback error snapin The snapin loop is not closed.
- Defective cabling to motor or encoder.
- Defective motor or encoder.
- Defective motor controller.
- Defective driver board. Check possible causes.
3217 %1 :\tCarrier not safe for move lift
Carrier is not positioned well on
the lift, after the carrier was in the
position to pick components out of
it.
- Carrier lost from puller tip.
- Sensor B3 not well adjusted. Check state of puller tip.
3218
%1 : Wafer handler
communication error
Error communicating with wafer
handler feedsection
- Hadware or software connection error
- Communication protocol error
- Check RS 232 connection between wafer handler section and machine
- Check communication port configuration
- Retry the operation
- If not correct, contact your service representative
3219 %1 : Wafer handler data error
Invailid message data for the
wafer handler feedsection is sent
or received
Communication protocol error, the data does not comply with
the communication interface of the wafer handler section
- Make a logdisk as described in the Service Manual
- Report error to your service representative
3220
%1 : Wafer handler command
failure
Reply message data of wafer
handler feedsection data indicates
operation failure Wafer handler is in wrong state
- Check wafer handler module for errors, warnings, etc.
- Retry the operation
- If not correct, make a logdisk as described in the Service Manual
- Restart the system
3221
%1 : Wafer handler servo power
failure
Servo power of wafer handler
feedsection can't be turned on/off Wafer handler is in wrong state
- Check wafer handler module for errors, warnings, etc.
- Retry the operation
- If not correct, restart the system
3222
%1 : Unable to remove wafer while
homing all wafer handler axes
Wafer handler feedsection cannot
home all axes Selected wafer cannot be removed
- Check wafer handler module for errors, warnings, etc.
- Retry the operation
- If not correct, restart the system
3223
%1 : Unsafe to home all wafer
handler axes
Wafer handler feedsection cannot
home all axes It is not safe now to home all the wafer handler's axes
- Check wafer handler module for errors, warnings, etc.
- Retry the operation
- If not correct, restart the system
3224
%1 : No parts available of selected
die type
Wafer handler feedsection cannot
offer the requested dies No pickable dies of the required type left on the wafer(s)
- Replace the empty or bad wafer(s) in the wafer handler cassette
- Retry the operation
3225
%1 : Operational wafer handler
error
A machine malfunction occurred
on the wafer handler feedsection Wafer handler is in wrong state
- Check wafer handler module for errors, warnings, etc.
- Retry the operation
- If not correct, make a logdisk as described in the Service Manual
- Restart the system
3226
%1 : Unable to home wafer
handler axes
Wafer handler feedsection cannot
home all axes Wafer handler is in wrong state
- Check wafer handler module for errors, warnings, etc.
- Retry the operation
- If not correct, restart the system
3227
%1 : Wafer handler die setup
changeover failed
Wafer handler feedsection does
not accept current die setup
- Wafer handler is in wrong state
- Invalid die setup in action spec of current order
- Check wafer handler module for errors, warnings, etc.
- Check die setup in machine action spec
- Retry the operation
3228
%1 : Unable to enter normal offline
state on wafer handler
Not possible to change the wafer
handler state to OFFLINE -
NORMAL Wafer handler is in wrong state
- Check wafer handler module for errors, warnings, etc.
- Retry the operation
3229
%1 : Unable to enter abnormal
offline state on wafer handler
Not possible to change the wafer
handler state to OFFLINE -
ABNORMAL Wafer handler is in wrong state
- Check wafer handler module for errors, warnings, etc.
- Retry the operation
3230
%1 : Unable to enter normal
production state on wafer handler
Not possible to change the wafer
handler state to PRODUCTION -
NORMAL Wafer handler is in wrong state
- Check wafer handler module for errors, warnings, etc.
- Retry the operation
3231
%1 : Unable to enter dry
production state on wafer handler
Not possible to change the wafer
handler state to PRODUCTION -
DRY Wafer handler is in wrong state
- Check wafer handler module for errors, warnings, etc.
- Retry the operation
3232
%1 : Unable to shutdown wafer
handler
Waffer handler feed section does
not accept shutdown command Wafer handler is in wrong state
- Check wafer handler module for errors, warnings, etc.
- Retry/skip the operation
3233
%1 : Wafer handler not able to
prepare requested dies
Production cycle command ( Pick
Die ) cannot be executed by wafer
handler
Wafer handler is in wrong state or its production sequence is
not correct
- Check wafer handler module for errors, warnings, etc.
- Retry the operation
- If not correct, make a logdisk as described in the Service Manual
- Restart the system
3234
%1 : Wafer handler not able to
transfer requested shuttle
Production cycle command (
Request Die ) cannot be executed
by wafer handler
Wafer handler is in wrong state or its production sequence is
not correct
- Check wafer handler module for errors, warnings, etc.
- Retry the operation
- If not correct, make a logdisk as described in the Service Manual