ERR-LIST-ACM.pdf - 第6页
511 Transport :\tCommunication time- out run-out The servo system of the transport run-out section reacts too slow. - Transport controller hardware error. - Retry and continue. - Restart the system. - Report error to you…

401 Setup check failed
The feeder, transport and/or head
setup is not verified or differs from
the previous used setup.
- The feeder setup must be verified. The used setup differs
from the previously used (No family or other family).
- The transport setup is checked by the system; the currently
used setup may differ.
- The toolbit setup is checked by the system, the curr
- Use skip action if you are sure that the setup is correct, otherwise verify the
setup.
402
Order not started, still machine
errors pending or some modules
not calibrated
- The process controller state
needed to download an action
specification is not reached.
- Machine errors are pending.
- One or more modules are not calibrated.
- Retry action.
- Calibrate the not calibrated modules.
- Restart the system.
403 Action spec download failed System failure.
- Corrupted file system.
- Illegal update has been occurred. - Contactl your service representative.
501 Transport :\tposition error lift
The servo system of the transport
lift is not able to move to the
requested position, or the servo
system has detected a position
failure, which exceeds the error
limit.
- The requested position is outside the mechanical range.
- The friction of the lift mechanics is too high.
- The servo system is defective. - Maintenance is required in case of a friction problem.
502 Transport :\ttracking warning lift.
The lift servo system has detected
a position failure, which exceeds
the warning limit.
- The friction of the lift mechanics is increasing; maintenance
may be required. - Maintenance is required.
503 Transport :\tLift not calibrated
An attempt was made to move the
lift while the lift was not calibrated.
- The transportsystem was not calibrated.
- Defective transport controller.
- Calibrate the lift.
- If error still occurs, replace transport controller.
504
Transport :\tcommunication time-
out lift.
The servo system of the transport
lift reacts too slow. - Hardware error on transport controller.
- Retry and continue.
- Restart the system
- Contact your service representative.
505
Transport :\tCommunication error
lift
Communication error occurred
inside the transport controller.
- Wrong parameters sent to servo controller; this error should
not occur.
- Retry and continue.
- Restart the system
- Report error to your service representative.
506
Transport :\tZero coarse not found
at homing lif.
During lift homing the zero coarse
sensor (EPD) could not be
located.
- EPD is defective.
- EPD wiring malfunction.
- Lift hardware failure.
- Retry and continue.
- Restart the system
- Contact your service representative.
507
Transport :\tZero fine not found at
homing lif.
During lift homing the zero fine
index on the encoder could not be
located. - Lift hardware failure.
- Retry and continue.
- Restart the system
- Contact your service representative.
509 Transport :\tposition error run-out
The servo system of the transport
run-out is not able to move to the
requested position
- Run-out belt jammed.
- The friction of the run-out mechanics is too high
- The servo system is defect.
- Check run-out mechanics for being jammed.
- Maintenance or repair is required.
- Contact your service representative.
510
Transport :\ttracking warning run-
out
The run-out servo system has
detected a position failure.
- The friction of the run-out mechanics is increasing;
maintenance may be required. - Maintenance is required.

511
Transport :\tCommunication time-
out run-out
The servo system of the transport
run-out section reacts too slow. - Transport controller hardware error.
- Retry and continue.
- Restart the system.
- Report error to your service representative.
512
Transport :\tCommunication error
run-out
Communication error occurred
inside the transport controller.
- Wrong parameters sent to servo controller; this error should
not occur.
- Retry and continue.
- Restart the system
- Report error to your service representative.
513 Transport :\tposition error width
The servo system of the transport
width is not able to move to the
requested position.
- The requested position is outside the mechanical range.
- The friction of the width mechanics is too high.
- The servo system is defect.
- Retry and continue.
- Restart the system.
- Contact your service representative.
514 Transport :\ttracking warning width
The width servo system has
detected a position failure. - The friction of the width mechanics is increasing.
- Maintenance is required.
- Retry and continue.
- Restart the system.
515
Transport :\tHome width position
lost.
An attempt was made to adjust the
transport width, while the transport
width was not calibrated.
(Width calibration is automatically
initiated by the system, prior to
width adjustments.)
- An attempt to home the width failed (no servo power, or
boards presented in the machine).
- Hardware failure.
- Internal error.
- Enter the dialogue machine set-up : user is prompted for width homing.
- Activate run-out and start the machine.
- Retry the operation
516
Transport :\tCommunication time-
out width
The servo system of the transport
width reacts too slow. - Hardware error on transport controller.
- Retry and continue.
- Restart the system.
- Report error to your service representative.
517
Transport :\tCommunication error
width.
Communication error occurred
inside the transport controller.
- Wrong parameters sent to servo controller; this error should
not occur.
- Retry and continue.
- Restart the system
- Report error to your service representative.
518
Transport :\tUnable to calibrate
width
During width homing the zero
coarse sensor (EPD) could not be
located.
- EPD defective
- EPD wiring malfunction.
- Width hardware failure.
- Retry and continue.
- Restart the system.
- Contact your service representative.
519
Transport :\ttimeout occurred
during width calibration
The width calibration has a time-
out. Width calibration is
automatically initiated when
needed, i.e. transport width is set
and the transport width servo
system has never been calibrated
before. - The movement class for transport width calibration is too slow. - Adjust the movement class for transport width calibration.
520
Transport :\tposition error work-
area
The servo system of the transport
work-area is not able to move to
the requested position.
- Transport belt in work-area is jammed.
- The friction of the transport mechanics is too high
- The servo system is defect.
- Check transport mechanics for being jammed.
- Maintenance or repair is required.
- Contact your service representative.
521
Transport :\ttracking warning work-
area
The work-area servo system has
detected a position failure. - The friction of the work-area mechanics is increasing - Maintenance is required.
522
Transport :\tCommunication time-
out work-area
The servo system of the transport
work-area section reacts too slow. - Transport controller hardware error.
- Retry and continue.
- Restart the system.
- Report error to your service representative.

523
Transport :\tCommunication error
work-area
Communication error occurred
inside the transport controller.
- Wrong parameters sent to servo controller; this error should
not occur.
- Retry and continue.
- Restart the system.
- Report error to your service representative.
524 Transport :\tposition error run-in
The servo system of the transport
run-in is not able to move to the
requested position
- Run-in belt jammed.
- The friction of the run-in mechanics is too high.
- The servo system is defect.
- Check run-in mechanics for being jammed.
- Maintenance or repair is required.
- Contact your service representative.
525
Transport :\ttracking warning run-
in
The run-in servo system has
detected a position failure. - The friction of the run-in mechanics is increasing - Maintenance is required.
526
Transport :\tcommunication time-
out run-in
The servo system of the transport
run-in section reacts too slow. - Transport controller hardware error.
- Retry and continue.
- Restart the system.
- Report error to your service representative.
527
Transport :\tCommunication error
run-in
Communication error occurred
inside the transport controller.
- Wrong parameters sent to servo controller; this error should
not occur.
- Retry and continue.
- Restart the system.
- Report error to your service representative.
528
Transport :\tamplifier lift/width
disabled.
The amplifier of the lift/ width servo
system is disabled. - Software error.
- Retry and continue.
- Restart the system.
- Report error to your service representative.
529
Transport :\tamplifier run-in/work-
area disabled.
The amplifier of the servo system
of the run-in/work-area section is
disabled. - Software error.
- Retry and continue.
- Restart the system.
- Report error to your service representative.
530
Transport :\tamplifier run-out
section disabled.
The amplifier of the run-out servo
system is disabled. - Software error.
- Retry and continue.
- Restart the system.
- Report error to your service representative.
531 Transport :\tZero drift run-in
The servo system of the run-in has
detected, that the zero-index has
changed.
- Disruption on the servo wiring.
- Encoder error.
- Hardware error.
- Check/exchange wiring.
- Check/exchange motor-encoder combination.
- Check/exchange transport controller.
532 Transport :\tZero drift work-area
The servo system of the work-area
has detected that the zero-index
has changed.
- Disruption on the servo wiring.
- Encoder error.
- Hardware error.
- Check/exchange wiring.
- Check/exchange motor-encoder combination.
- Check/exchange transport controller.
533 Transport :\tZero drift width
The servo system of the width has
detected that the zero-index has
changed.
- Disruption on the servo wiring.
- Encoder error.
- Hardware error.
- Check/exchange wiring.
- Check/exchange motor-encoder combination.
- Check/exchange transport controller.
534 Transport :\tZero drift lift
The servo system of the lift has
detected, that there is a mismatch
between the calibrated value and
the physical value.
- Disruption on the servo wiring.
- Encoder error.
- Hardware error.
- Check/exchange wiring.
- Check/exchange motor-encoder combination.
- Check/exchange transport controller.