3177 %1 :\tUnexpected toolbit attached Toolbit attached to the head, while trying to get a new toolbit from the toolbit exchange unit. - Toolbit not removed from the head during toolbit exchange action. - Remove toolbit …

3167
%1 :\tComponent Mismatch
(sides)
Mismatch between the component
description and the measured
component characteristics.
Distance between the sides - Wrong component description used. - Verify component and component description by SHOW function.
3168
%1 :\tOne or more component
side(s) not found
One or more component side(s)
could not be recognized
- Wrong component attached
- Wrong component description used
- Search window too small (reject level)
- Bad lighting conditions
- Verify component and component description by SHOW function
- Adjust reject level
- Adjust light levels
3169 %1 :\twrong shape
- No correct shape can be
deducted from sides. - Recognized sides do no intersect. - Check component description.
3170
%1 :\tLine fit error on component
side Cannot fit line on recognized side
- Wrong component attached
- Wrong component description used
- Bad light settings
- Ruler intersection not on one line
- Verify component and component description by SHOW function
- Change illumination level or type
- Change threshold
- Change ruler offset
3171 %1 :\tComponent lost before flux
Component is lost before the flux
is applied.
- Wrong toolbit is used.
- Vacuum leakage in the toolbit.
- Look where the component is. When on head, leave it there, it will be
dumped automatically on the re-use pallet.
- Check used toolbit for vacuum leakage.
- Retry.
3172 %1 :\tComponent lost after flux
Component is lost after applying
flux to it.
- Wrong toolbit is used.
- Vacuum leakage in the toolbit.
- Too much flux on drum.
- Look where the component is. When on head, leave it there, it will be
dumped automatically on the reuse pallet.
- Check used toolbit for vacuum leakage.
- Retry.
3173
%1 :\tToolbit too big to fit in toolbit
exchange unit
Toolbit does not fit in toolbit
exchange unit.
Putting this toolbit in the toolbit
exchange unit may cause serious
damage to the toolbit, head or
toolbit exchange unit. - Not supported toolbit size. - Exchange the toolbit manually.
3174 %1 :\tFiducial not measured
The fiducial could not be
measured by the vision system.
- No fiducial has been found.
- Bad colour (polarity) of fiducial (Black or White).
- Wrong light level.
- Check the fiducial by using the setup vision menu, to see if the light level and
the polarity are correctly specified in the fiducial file.
- Check if the board is stopped on the correct position in the transport system.
- Re-position FA camera (by ad
3175
%1 :\tRequested toolbit not found
in Toolbit exchange unit
The needed toolbit is not available
in Toolbit exchange unit. _The needed toolbit is not available. - Put toolbit in unit, use SETUP - TOOLBIT functions.
3176 %1 :\tFiducial size not correct
Mismatch between measured
fiducial size and measured size.
- Wrong fiducial.
- Wrong description. - Modify description.

3177 %1 :\tUnexpected toolbit attached
Toolbit attached to the head, while
trying to get a new toolbit from the
toolbit exchange unit.
- Toolbit not removed from the head during toolbit exchange
action.
- Remove toolbit manually, or
- Retry toolbit exchange action.
3178
%1 :\tNot enough free space
around fiducial
The interpolation (or 'Synthetic
Edge') algorithm requires a
minimum free space of 40 pixels
around the fiducial.
- Board is dirty near the fiducials.
- Bad light conditions.
- Clean fiducial.
- Adapt light setting in fiducial description file.
3179
%1 :\tImage quality not good
enough for feature recognition
Too many black/white crossovers
in image, or contrast too low to
recognize bumps.
- Lighting (level and type of illumination) or threshold settings
are wrong.
- Component features out of spec.
- Change bump threshold settings : higher for too bright images / lower for too
dark images.
- Change illumination level and/or type.
3180
%1 :\tImage quality not good
enough for feature recognition
Too many black/white crossovers
in image, or contrast too low to
recognize bumps.
- Lighting (level and type of illumination) or threshold settings
are wrong.
- Component features out of spec.
- Change bump threshold settings : higher for too bright images / lower for too
dark images.
- Change illumination level and/or type.
3181
%1 :\tComponent outline detection
failed
The initial estimation of the
component contour (based on
outer bumps) failed.
- Bump area limits not correctly specified.
- Too many disturbing (bright) objects at border of component.
- Check specified bump areas.
- Change illumination type or intensity.
3182
%1 :\tComponent outline detection
failed
The initial estimation of the
component contour (based on
outer bumps) failed.
- Bump area limits not correctly specified.
- Too many disturbing (bright) objects at border of component.
- Check specified bump areas.
- Change illumination type or intensity.
3183 %1 :\tbump line fitting failed
- The bumps used for alignment
cannot be fitted on one line.
- Bumps are not located on one line.
- There are less than 2 bumps for a particular component side.
- Change bump alignment parameters in component description (threshold,
light intensity, border range).
3184 %1 :\tbump line fitting failed
- The bumps used for alignment
cannot be fitted on one line.
- Bumps are not located on one line.
- There are less than 2 bumps for a particular component side.
- Change bump alignment parameters in component description (threshold,
light intensity, border range).
3185
%1 :\tNot enough bumps for
alignment
- The initial number of detected
bumps in the border range is not
enough to start alignment on.
- The initial number of detected bumps on one side is less than
the defined minimum number of alignment bumps
for that side.
- Define lower number of required alignment bumps.
- Improve light settings and/or threshold or bump area definitions.
3186
%1 :\tNot enough bumps for
alignment
- The initial number of detected
bumps in the border range is not
enough to start alignment on.
- The initial number of detected bumps on one side is less than
the defined minimum number of alignment bumps for that side.
- Define lower number of required alignment bumps.
- Improve light settings and/or threshold or bump area definitions.
3187 %1 :\tbump pattern too large
- Number of bumps is too large for
bump checking algorithm. - Too many or too large bump matrices specified. - Define less matrices or bumps.
3188 %1 :\tbump pattern too large
- Number of bumps is too large for
bump checking algorithm. - Too many or too large bump matrices specified. - Define less matrices or bumps.
3189 %1 :\tno bump match
- One or more bumps cannot be
matched with expected bump
during bump checking.
- No bump present or too many bumps (objects) found at
expected position.
- Bad component quality.
- Adjust matrix definition.
- Check component quality.

3190 %1 :\tno bump match
- Number of bumps is too large for
bump checking algorithm.
- No bump present or too many bumps (objects) found at
expected position.
- Bad component quality.
- Adjust matrix definition.
- Check component quality.
3191
%1 :\tToolbit too big for coplanarity
actions
Toolbit does not fit in the
coplanarity unit. Using this toolbit
for coplanarity actions may cause
serious damage to the toolbit,
head or coplanarity unit. - Not supported toolbit size Update action spec
3192
%1 detected an unexpected
collision
During Toolbit exchange, the head
detected an impact with an object
while lowering the head. - A toolbit is in a toolbit exchange location that should be empty.
- Update the toolbit exchange data, or
- Remove / replace the unexpected toolbit from the toolbit exchange unit.
3193 %1 did not detect a touchdown
The head did not detect an impact
within the specified search area.
- The impact surface is not present.
e.g. during picking from tray, no component is present in tray
pocket.
during fetching a toolbit while executing a toolbit
exchange, no toolbit is present in the toolbit pocket - Check if the requested part is present on the machine.
3195 Invalid feeder file
The system encountered invalid
data in a feeder control file of a
feeder that is used in the action
spec.
- Syntax error in feeder control file.
- Value out of range. - Check the feeder file.
3197 %1 :\tFeeder in error
One of feeders in the feeder
section reported an error. - Problem on feeder. - Solve the error cause.
3199
Restoring XY calibration data
failed
The data to restore has arrived on
the aPC, but the processing of this
data has failed.
- Original data could not be backed up.
- Current calibration values could not be invalidated.
- New calibration data could not be used.
- If the original data files were all backed up, restore these files manually and
restart the machine.
- Otherwise, the machine still has valid calibration data. Try to restore again
when the problem that caused the backup to fail is solved.
3200 MIS data collection failed
The MIS data collection failed, no
MIS data is retrieved from the
system. The MIS data for this
order period is not reliable.
- Disk full.
- Illegal file modifications by user.
- System communication error.
- No current order available on the system, or no previous order
selected.
- Check disk capacity.
- Check if there is a current order on the system, or if one is selected.
3201
RETRY INFORMATION\x0ANo
extra information available
3202
RETRY INFORMATION\x0AHead
: %1\x0ASection : %2\x0AFeeder :
%3\x0AChannel :
%4\x0AComponent : %5\x0A