1OM-1625-004_w.pdf - 第186页

1OM-1603 4-9 1. Specications : Chap.4 1012-005 Item Description High-Speed Head Multi-Functional Head 13. Placement Heads Equipped with 2 heads / 2 beams Vacuum Nozzle: Max. 15 nozzles on each head Ref. : Number of Comp…

100%1 / 219
1OM-1603
4-8
1. Specications : Chap.4
1007-004
Item Description
(2) Packaged Posture Standards
Taped Components JIS or its equivalent
v Paper Tapes (Width : 8 mm)
v Embossed Tapes (Width : 8 to 72 mm)
v Reel Outer Diameter : F382 mm or less
Note : Some taping sizes are limited.
Some taped components cannot be used due to the mechanical
characteristics.
Stick Components
v Carrier Stick :
Width 8 to 60 mm × Thickness 3 to 16 mm × Length 400 to 600 mm
Tray Components
v Tray : 100 s 100 to 323 s 136 mm
(In the case of using the JEDEC multi-layer tray feeder)
100 s 100 to 330 s 230 mm
(In the case of using the full size multi-layer tray feeder)
T1E1-8
1OM-1603
4-9
1. Specications : Chap.4
1012-005
Item
Description
High-Speed Head Multi-Functional Head13. Placement Heads
Equipped with 2 heads / 2 beams
Vacuum Nozzle: Max. 15 nozzles on
each head
Ref. : Number of Component Picks:
Component Size
No. of
Component
Picks
4.2 × 4.2 mm or less 15
to 8 × 8 mm or less 7
to 9 × 9 mm or less 5
to 10 × 10 mm or less 4
to 12 × 12 mm or less 3
to 20 × 20 mm or less 2
to 44 × 44 mm or less 1
Note : There are high-speed nozzle
and middle-size odd shaped
nozzle for vacuum nozzle
types.
Although the high-speed
nozzles and middle-size odd
shaped nozzles can be
arranged together on a single
head, the middle-size odd
shaped nozzles must be
attached, leaving one out of
two pitches empty due to the
locations of the diffusion
plates.
High-Speed Nozzle :
The diameter should
be 6 mm or less.
This nozzle is used for
0402 component up to
the size 20
× 20 mm.
Middle-Size Odd Shaped
Nozzle :
The diameter is 12
mm or less. The
nozzle tip is processed
according to the
applicable
components.
The nozzle can be
used for the
component size of up
to 44 × 44 mm.
Equipped with 2 heads / 2 beams
Vacuum Nozzle: Max. 3 nozzles on
each head
Ref. : Number of Component Picks:
Component Size
26.2 × 26.2 mm or less 3
to 55 × 55 mm or less 2
Note : For components not within
the above ranges, the number
of components to be picked
up should be "1".
(In the case of connector 100
× 26 mm, etc.)
T1E1-9
1OM-1603
4-10
1. Specications : Chap.4
1012-005
Item
Description
High-Speed Head Multi-Functional Head14. Number of
Stocked Nozzles
Nozzle Stocker for High-Speed
Nozzle
Max. 15 nozzles can be stored for
each stocker.
Nozzle Stocker for Middle-Size
and Odd Shaped Nozzle
Max. 8 nozzles can be stored for each
stocker.
Notes : (a) Increase of the quantity
of nozzle to be stocked
is available by means of
adding the nozzle
stockers (option).
(b) When the middle-size
odd shaped nozzle are
used, the nozzle stockers
for the middle-size odd
shape nozzle are
required.
Nozzle Stocker for Multi-
Functional Nozzle
Max. 9 nozzles can be stored for
each stocker.
Notes : (a) Use the nozzle stocker
for multi-functional
nozzle.
(b) Increase of the quantity
of nozzle to be stocked
is available by means of
adding the nozzle
stockers (option).
15. Number of
Installable Feeders
(1) Tape Feeders
Max. 60 feeders (30 tape feeders × 2 feeder bases)
(when only 8 mm dual tape feeders are used)
Ref. : Up to 120 types of components can be loaded.
Max. 60 feeders (30 × 2 feeder bases)
(When only 12 / 16 mm tape feeders are used)
Max. 30 feeders (15 × 2 feeder bases)
(When only 24 / 32 mm tape feeders are used)
Max. 20 feeders (10 × 2 feeder bases)
(When only 44 / 56 mm tape feeders are used)
Max. 14 feeders ( 7 × 2 feeder bases)
(When only 72 mm tape feeders are used)
(2) Vibratory Stick Feeders
Max. 5 feeders / feeder base
Ref. : Up to 6 carrier sticks can be installed on one vibratory stick feeder.
Notes : (a) The number of installable feeders varies according to the
combination of the reel width for the taping and the feeders.
(b) Use the tape feeder for the SIGMA-G4/G5. In the case that the
tape feeder for the GXH series is used, the operational conditions
are partly restricted.
(c) The tape feeder, dual tape feeder and bulk feeder for the other
machines cannot be used.
T1E1-10