00194310-02_UM_Sleeve_Verification_de_en.pdf - 第21页

User manual verification of sleeves Adjusting the sensing lever gauge Sleeve Verification Ve rifizierung von Pinolen 21 1.3 Adjusting the sensing lever gauge ▪ Set the sensing lever gaug e at the c orrect distance for th…

100%1 / 30
User manual verification of sleeves
Overview
20 Sleeve Verification Verifizierung von Pinolen
1.2 Overview
Sleeve checking unit (part no.: 03019502-xx)
1. Base unit sleeve checking unit (part no.: 03019500-xx)
2. Lever gauge (part no.: 03019886
3. Add-on weight 0.2N (part no.: 03019641-xx)
4. Add-on weight 0.1N (part no.: 03019574-xx)
5. Allen key 2.5mm
6. Nozzle 720/920 (part no.: 00325972Sxx)
7. Check weight for lever gauge (part no.: 03041694-xx)
8. Base weight (part no.: 03019573-xx)
NOTICE
Type and source of the danger
The sleeve verification tool is a checking device, no measuring device. It is used to detect and
select sleeves with wrong spring tension by means of attributive check. It is not used to identify
exact measured values.
User manual verification of sleeves
Adjusting the sensing lever gauge
Sleeve Verification Verifizierung von Pinolen 21
1.3 Adjusting the sensing lever gauge
Set the sensing lever gauge at the correct distance for the sleeves to be measured (6x or 12x place-
ment head).
Positioning the sensing lever gauge for sleeves C&P12 / C&P6
1. Position for sleeve C&P12
2. Position for sleeve C&P6
3. Screw to fix sensing lever gauge
User manual verification of sleeves
Adjusting the sensing lever gauge
22 Sleeve Verification Verifizierung von Pinolen
The sensor lever gauge must be calibrated at the start of each set of measurements. First raise (1)
and then press the sensor lever down (2) against the stop.
After the adjustment, there is always a defined gap between the tip of the sensor lever and the stop
(3).
Setting the sensing lever gauge
NOTICE
This setting is important as it ensures the correct working range for the sensing lever gauge in
conjunction with the sleeve.