Vakuum Tooling AMKOR X4 OS Applikation.pdf - 第36页

Installation instructions Vacuum Tooling AM KOR (001885 01-01) SIPLACE X4 / OS Application 03/2006 Edition 36 Circuit diagram for wiring the option 2 2 Fig. 2.1 - 2 Wiring diagram vacuum tooling ( 00166215-xx)

100%1 / 56
Installation instructions Vacuum Tooling AMKOR (00188501-01) SIPLACE X4 / OS Application
03/2006 Edition
35
Working principle of the vacuum switch: 2
2
2
For programming, see 1.6.3. 2
If the vacuum threshold cannot be reached, then the placement process cannot be started. 2
Once the placement process has ended, the vacuum must be reduced to the set threshold (150
mbar) so that the lifting table can move down. 2
The vacuum threshold is only checked immediately after the lifting table has moved up. 2
A drop in vacuum during placement cannot be detected. 2
2
2
2
2
2
2
2
2
2
0 bar
- 1 bar
A 2
H 1
Output 1
Output 2
- 150 mbar
- 600 mbar
if 1==>
signal that
placement may start
if 1==>
signal that the lifting
table may be lowered
Installation instructions Vacuum Tooling AMKOR (00188501-01) SIPLACE X4 / OS Application
03/2006 Edition
36
Circuit diagram for wiring the option 2
2
Fig. 2.1 - 2 Wiring diagram vacuum tooling (00166215-xx)
Installation instructions Vacuum Tooling AMKOR (00188501-01) SIPLACE X4 / OS Application
03/2006 Edition
37
To avoid a crash situation between the conveyor and the vacuum tooling, the automatic width ad-
justment must be deactivated using SIPLACE Pro. 2
This involves changing Config.ma in the SRDaten/SRCMA directory. 2
2
2
2
Change from 1 to 0 2