Vakuum Tooling AMKOR X4 OS Applikation.pdf - 第53页

Installation instructions Vacuum Tooling AM KOR (00188501-01) SIPLACE X4 / OS Application 03/2006 Edition 53 2 Fig. 2.10 - 3 The vacuum cannot be fully dissipated after the placement process. T roubleshooting 2 – Check t…

100%1 / 56
Installation instructions Vacuum Tooling AMKOR (00188501-01) SIPLACE X4 / OS Application
03/2006 Edition
52
2
Fig. 2.10 - 2 Vacuum built up in placement area 1 is too low
Troubleshooting 2
Check whether all the vacuum holes are covered (the as-delivered setting allows placement
with just one vacuum hole open)
Check whether there are any components or dirt on the vacuum plate.
Installation instructions Vacuum Tooling AMKOR (00188501-01) SIPLACE X4 / OS Application
03/2006 Edition
53
2
Fig. 2.10 - 3 The vacuum cannot be fully dissipated after the placement process.
Troubleshooting 2
Check the vacuum tooling connections
Installation instructions Vacuum Tooling AMKOR (00188501-01) SIPLACE X4 / OS Application
03/2006 Edition
54
2
Fig. 2.10 - 4 Attention: The automatic width adjustment must be deactivated.
If the conveyor is moved manually, then this error message appears. The conveyor moves, even
though the vacuum tooling is fitted. 2
2
Risk of crashing. 2
2
2
2.11 Refitting the standard conveyor
Connectors X34/X35 should be removed so that the special design is no longer present for the
machine and the software works in standard mode.
Detach the hoses and remove the base plate from the lifting table together with the vacuum
elements.
Disconnect the air supply to the maintenance unit.
2