CP14 Head Part Exchange - Replacing the DP Drive en.pdf - 第19页

E-by SIPLACE CP14 Returning the CP14 Head Part Exchange 1/1 CAUTION! Refer to safety inst ructions in user manual before working on the machine. ESD guidelines are to be followed Tool: Wear Part: Consum ables: 1. Careful…

100%1 / 24
E-by SIPLACE CP14 Returning the Aperture Ring
Part Exchange
2/2
CAUTION! Refer to safety instructions in user manual before working on the machine.
ESD guidelines are to be followed
Tool: Wear Part: Consumables:
7. Refit the cover. Hand-tighten the screw fas-
tening the cover.
E-by SIPLACE CP14 Returning the CP14 Head
Part Exchange
1/1
CAUTION! Refer to safety instructions in user manual before working on the machine.
ESD guidelines are to be followed
Tool: Wear Part: Consumables:
1. Carefully lift the head into of the locating
pins on the head plate.
2. Tighten all four M4 fastening screws with a
long torx key.
3. Connect the pneumatic connections from
the placement head.
4. Carefully plug in the camera cable and fix
back the cable tie.
5. Connect the flat ribbon cable from the
placement head or head adapter.
6. Remove protective cap from the compo-
nent sensor of the placement head.