Fig.3.2 “Save Logged File” screen
* You can also save the feeder ID log data to a file at the "History utility" screen displayed by
tapping the [Setup] - [History] button.
3.1.3 “Reset” button
Through the following procedure, you can clear the feeder ID log data on the [Operator] or
[Service] tab.
1. Tap the [Reset] button to open the [Setting Reset Method] dialog box. Select the reset
method, and tap the [OK] button.
2. When a conformation dialog box displayed, tap the [Yes] button.
Fig.3.3 “Setting Reset Method” screen
3.1.4 “Option”
button
Tap the [Option] button to open the [Setting Grid View] screen that allows you to show or
hide each log data item. Check the items you want to display, and uncheck the items you do
not want to display.
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50281
6/13
Fig.3.4 “Setting Grid View screen
3.2 Feeder ID log file
The feeder ID log date is output to the following files automatically.
3.2.1 Feeder ID individual log file
History data of each feeder is output to the feeder ID individual log file (One file for each
feeder).
Contents
Feeder ID log data of each feeder
Output timing
When feeder is detached or machine is turned off.
Save path
Path specified in “feeder ID individual log” at “ID log setting” screen.
([Software Setting] - [History] tab - [Unit Log] button - [Log setting] button)
File name
(Feeder ID)_log.csv
Example: SSY-012-0001_log.csv
3.2.2 Feeder ID daily log file
History data of all used feeders is output day by day to the feeder ID daily log file.
Contents
Feeder ID log data of all feeders used on that day (Including the feeders
which are not set to this machine at the time of a file output)
Output timing
When machine is turned off or just after date changed.
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50281
7/13
Save path
Path specified in “Unit log Setting” screen
([Software Setting] - [History] tab - [Unit Log] button)
File name
FeederIDLog_(Machine serial number)_(Date).csv
() FeederIDLog_Y11111_20130608.csv
3.2.3 Feeder ID log backup file
History data of feeders set to this machine is output to the feeder ID log backup file.
Contents
Feeder ID log data of all feeders set to this machine.
Output timing
When machine is turned off or just after date changed.
Save path
D:¥Machine¥My History
File name
FeederIDLog_local.csv
3.3 Feeder ID log file format
The format of the feeder ID log is as follows.
The file format is the same among the feeder ID individual log file, the feeder ID daily log
file, the feeder ID log backup file and the file saved by the [log save] button.
Table3.2 Feeder ID log file format
No.
Item name
E
Header section First line
1 Version Version of file format. Example: “V3.03”
2 Type of feeder set number
[Soft]” is output when “Feeder SetNo” (No.12) is
output by soft no. ” [User]is output when it is output
by user no. (See ”Setting Detail History” screen of
4.3 about setting method)
3 Multi-language notation
When multi-language mode: “MultiLanguage”
When not multi-language mode: Nothing is output
Item name section Second line
4 Language
When multi-language mode: “EN”(When English)
When not multi-language mode: Nothing is output
5 Item name of data section
Item names of data section (No.6~No.47) are
output.
Data section
After third line
When outputting plural feeder data, plural lines are
outputted.
6 Language
When multi-language mode: “EN”(When English)
When not multi-language mode: Nothing is output
7 Feeder ID Feeder ID is output.
8 Feeder Type Name Feeder type is output by name.
9 Feeder Type Feeder type is output by type number.
10 Parts Name Parts name attached to the feeder is output.
11 Machine No Serial number of the mounter is output.