TK26620.Feeder ID Log Function Specification.pdf - 第8页

SMT Software Engineering Group IM Operations YAMAHA M OTOR CO., LTD. MDOC-SOFT50281 8/13 No. Item name Explanation 12 F eeder Set No Set pos ition number of att ached feeder i s output. 13 Cart N o Cart numb er of atta c…

100%1 / 13
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50281
7/13
Save path
Path specified in “Unit log Setting” screen
([Software Setting] - [History] tab - [Unit Log] button)
File name
FeederIDLog_(Machine serial number)_(Date).csv
() FeederIDLog_Y11111_20130608.csv
3.2.3 Feeder ID log backup file
History data of feeders set to this machine is output to the feeder ID log backup file.
Contents
Feeder ID log data of all feeders set to this machine.
Output timing
When machine is turned off or just after date changed.
Save path
D:¥Machine¥My History
File name
FeederIDLog_local.csv
3.3 Feeder ID log file format
The format of the feeder ID log is as follows.
The file format is the same among the feeder ID individual log file, the feeder ID daily log
file, the feeder ID log backup file and the file saved by the [log save] button.
Table3.2 Feeder ID log file format
No.
Item name
E
Header section First line
1 Version Version of file format. Example: “V3.03”
2 Type of feeder set number
[Soft]” is output when “Feeder SetNo” (No.12) is
output by soft no. ” [User]is output when it is output
by user no. (See ”Setting Detail History” screen of
4.3 about setting method)
3 Multi-language notation
When multi-language mode: “MultiLanguage”
When not multi-language mode: Nothing is output
Item name section Second line
4 Language
When multi-language mode: “EN”(When English)
When not multi-language mode: Nothing is output
5 Item name of data section
Item names of data section (No.6~No.47) are
output.
Data section
After third line
When outputting plural feeder data, plural lines are
outputted.
6 Language
When multi-language mode: “EN”(When English)
When not multi-language mode: Nothing is output
7 Feeder ID Feeder ID is output.
8 Feeder Type Name Feeder type is output by name.
9 Feeder Type Feeder type is output by type number.
10 Parts Name Parts name attached to the feeder is output.
11 Machine No Serial number of the mounter is output.
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50281
8/13
No.
Item name
Explanation
12 Feeder SetNo Set position number of attached feeder is output.
13 Cart No Cart number of attached feeder is output.
14 Cart Set No
Set position number of attached feeder in cart is
output. (Relative position in cart)
15 Location 0 fixed (Not in use)
16 Use Status 0 fixed (Not in use)
17 [user] Count
User mode: Number of times of feeder drive is
output.
18 [user] Pick Error User mode: Number of pick error is output.
19 [user] Parts Error User mode: Number of vision error is output.
20 [user] NoParts Error User mode: Number of no-parts error is output.
21 [user] Nozzle Error User mode: Number of nozzle error is output.
22 [user] Date
User mode: Date when measurement was started is
output.
23 [user] Last Update Date User mode: Last update date is output.
24 [user] Stroke Length / Feed Time
User mode: Distance of the tape sent by the feeder
(In case of a multi stick feeder, feeding time) is
output.
25 [user] Smart Exist Count
User mode: Number of feeder attachment times is
output.
26 [user] After Adjust Drive Cnt
User mode: Number of times of feeder drive after
adjusting by SS Tune-Up Station is output.
27 [Maintenance] Count
Maintenance mode: Number of times of feeder drive
is output.
28 [Maintenance] Pick Error Maintenance mode: Number of pick error is output.
29 [Maintenance] Parts Error Maintenance mode: Number of vision error is output
30 [Maintenance] NoParts Error
Maintenance mode: Number of no-parts error is
output
31 [Maintenance] Nozzle Error
Maintenance mode: Number of nozzle error is
output.
32 [Maintenance] Date
Maintenance mode: Date when measurement was
started is output.
33 [Maintenance] Last Update Date Maintenance mode: Last update date is output.
34
[Maintenance] Stroke Length /
Feed Time
Maintenance mode: Distance of the tape sent by the
feeder (In case of a multi stick feeder, feeding time)
is output.
35 [Maintenance] Smart Exist Count
Maintenance mode: Number of feeder attachment
times is output.
36
[Maintenance] After Adjust Drive
Cnt
Maintenance mode: Number of times of feeder drive
after adjusting by SS Tune-Up Station is output.
37 [total] Count
Total mode: Number of times of feeder drive is
output.
38 [total] Pick Error Total mode: Number of pick error is output.
39 [total] Parts Error Total mode: Number of vision error is output
40 [total] NoParts Error Total mode: Number of no-parts error is output.
41 [total] Nozzle Error Total mode: Number of nozzle error is output.
42 [total] Date
Total mode: Date when measurement was started is
output.
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50281
9/13
No.
Item name
Explanation
43 [total] Last Update Date Total mode: Last update date is output.
44 [total] Stroke Length / Feed Time
Total mode: Distance of the tape sent by the feeder
(In case of a multi stick feeder, feeding time) is
output.
45 [total] Smart Exist Count
Total mode: Number of feeder attachment times is
output.
46 [total] After Adjust Drive Cnt
Total mode: Number of times of feeder drive after
adjusting by SS Tune-Up Station is output.
47 Cumulated Drive Cnt Number of times of past feeder drive is output.
4. Setting
When using the feeder ID log, perform the following settings.
4.1 Setting in “ID log setting” screen
Tap [Setup] - [Software Setting] button - [History] tab - [Unit Log] button - [Log Setting]
button and open “ID Log Setting” screen. Enable the maintenance notice function and set
the feeder ID individual log file path to “Server Path”.
Fig.4.1 “History” tab of “Software Setting” screen