5 Restrictions  Bedienungsanleitung OSC Package User Guide OSC-Paket 05/2019 99 5 Restrictions ● The increased placement force to 100 N is only possible for the Twin VHF placement head, item no [03096701-03] . Placement…

100%1 / 104
4 Working with the OSC Features
4.11 Component Chipping Detection (from R19-1)
98 Bedienungsanleitung OSC Package User Guide OSC-Paket 05/2019
4.11 Component Chipping Detection (from R19-1)
The component chipping detection functionality checks whether the edge of a component has lar-
ger deviations than defined. It can be enabled or disabled using the Chipping detection checkbox in
the Vision Inspection tab of the Component Shape Editor of SIPLACE Pro Desk.
Restrictions
●
Only supported for vision types BareDie, BGA, CCGA, Chip, Moulded, Nonstandard.
●
The OSC license must be available.
5 Restrictions
Bedienungsanleitung OSC Package User Guide OSC-Paket 05/2019 99
5 Restrictions
●
The increased placement force to 100 N is only possible for the Twin VHF placement head,
item no[03096701-03]. Placements with a force greater than 70 N are not supported on sta-
tions with software versions < 710 and Twin VHF placement heads with a functional status <
[-03]. Such placements will be forced onto stations with station software version >= 710 by
SIPLACE Pro.
●
The increased placement force to 30 N for the TH placement head from R18-2 is not suppor-
ted on the SIPLACE X-Series placement machines.
●
The improved teaching procedure for placement of snap-in components from R18-2 is not
supported on the SIPLACE CA4 / CA4 V2 placement machines.
●
Placement of components with centering pins (Pin in Paste height check) is not supported on
the SIPLACE CA4 / CA4 V2 placement machines.
●
Station software version 712.0 is required for the 4x image capture option in the stereo meas-
urement. This option is not supported in the compatible 711.2© mode.
●
As of R19-1, exceptionally high components are placed only by the last station of the line. If
components are placed by a CPP placement head no Twin or Twin VHF placement head
must be used in the same placement area.
5 Restrictions