Retrofit / Maintenance Instructions SIPLACE HS-50 / HS-60
1 Retrofit / Maintenance Instructions Air filter box with more powerful fan 04/2004 US Edition
24
: Lift up the lid.
1
: Pull the old filter mat (with filter frame) away from the Velcro strip along the edge of the lid
frame.
: Remove any filter mat residues and other attached parts from the Velcro surface.
: Fix the new filter mat (item no. 00315209-01), which is supplied already fixed to a filter frame,
to the lid frame using the Velcro strip.
: Reattach the lid.
1.7.3 Vacuum the air filter mats, weekly
: Switch the placement machine off at the main switch.
1
Follow the correct shut-down routine. 1
1
1
: Secure the placement machine to prevent it being switched on without authorization during the
maintenance.
: Visually check that all 4 fans have stopped.
: Open and remove the lid of the air filter box as described above.
: Use a vacuum cleaner with a wide nozzle and thoroughly vacuum the top of the filter mat once
a week.