PCB alignment unit for SIPLACE S-27 HM / HS-60 / HF-series / X-series / D-series Edition 11/2006 31 : V ent the lifting table cylinders in placement area 2 by detachi ng the two air hoses. This will make it easier to sub…

PCB alignment unit for SIPLACE S-27 HM / HS-60 / HF-series / X-series / D-series
Edition 11/2006
30
2.5 Retrofit
: Set the conveyor width to 200 mm.
: Switch the placement machine off at the main switch.
: Move the gantry over the pick-up area.
: Unscrew the four screws to remove the lifting table bed.
2
2
The following modules only have to be fitted in the HS-60 / D4: 2
2
: Unscrew the plastic springs on the right and left of the lifting table bed.
: Place a 3 mm plain washer beneath each spring and then screw in once more.
Plastic spring
Plain washer 3 mm
DIN 7349
Plastic spring
Plain washer 3 mm
DIN 7349
2
2

PCB alignment unit for SIPLACE S-27 HM / HS-60 / HF-series / X-series / D-series
Edition 11/2006
31
: Vent the lifting table cylinders in placement area 2 by detaching the two air hoses. This will
make it easier to subsequently fit the path limiter.
2
2
2
The following procedure has to be done on each machine type:
2
Fitting the ‘path limiter slat’ 2
This slat limits the free moving space from ‘stopp
er PCB adjustment’ to the top. 2
2
Some types of machine and placement areas require different path limiters: 2
S-27 HM:
PA1: Fix module with spacer (61 mm) Item no. 00366561-xx 2
HS-60 / D4:
PA1: Fix module with block (30 mm) Item no. 00366480-xx
PA2: Fix module with block (14 mm) Item no. 00366478-xx 2
HF-series / X-series / D3:
PA1: Fix module with spacer (55 mm) Item no. 00371982-xx
PA2: Fix module with spacer (71 mm) Item no. 00371983-xx 2
D1 / D2:
PA1: Fix module with spacer (60 mm) Item no. 03053481-xx
2
2

PCB alignment unit for SIPLACE S-27 HM / HS-60 / HF-series / X-series / D-series
Edition 11/2006
32
: Disassembly the lifting table.
: Fix the block/spacer colocate with ‘path limiter slat
’ on the end face of the lifting table.
2
On S-27 HM, this path limiter is L-shaped.
Fit it with the longer limb at the top. 2
Hole for path limiter
Fitted path limiter
2
2
Fig. 2 - 1 Sample picture from HS-60 placement area 1 (similar to other conveyor types)