ANSI/ESD S20.20- 2021 16 (This annex is no t part of ESD Association Standard ANSI/ESD S20.20- 202 1) ANNEX D (INFORMATIV E) – RELATED DOCU MENTS The follow ing doc uments are li sted for further reference. Some document…

100%1 / 28
ANSI/ESD S20.20-2021
15
Technical Rationale for Deviation: The ESD sensitivity of wafers in front-end manufacturing
operations is significantly lower than after the die are separated. A ceiling-based room ionization
system is used in the EPA's covered in this ESD Control Plan. The purpose of this system is
primarily for contamination control. It will be utilized for reducing the charge on the many process
essential insulators typically present in any wafer fabrication facility. A wide-coverage (versus point-
of-use) ionization system is critical in any wafer fabrication facility to reduce electric fields on the
many process essential insulators. In limited critical operations where a tighter offset is deemed
required by engineering or the ESD program manager, peak ionizer offset voltage maximum
specification is ± 35 Volts.
Examples of Unacceptable or Unnecessary Tailoring Statements and Rationale
Example 1
Tailoring Statement: Seating as an ESD control item is not required because all personnel must
wear a grounded wrist strap when seated inside an EPA.
ANSI/ESD S20.20 Requirement Affected: Section 8.2 (personnel grounding), second paragraph:
"When personnel are seated at ESD protective workstations, they shall be connected to the
selected grounding / equipotential bonding system via a wrist strap system."
Why is this Tailoring Statement Unnecessary? The standard does not require ESD protective
seating. ESD protective seating is one of many 'optional' ESD control items for EPAs provided in
Table 3 of the standard. The actual requirement is for seated personnel to be connected to a
grounded wrist strap, and this is independent of whether ESD protective seating is used.
Example 2
Tailoring Statement: Nonessential insulators are not allowed inside the organization's EPAs in
designated areas.
ANSI/ESD S20.20 Requirement Affected: Section 8.3.1 (insulators), first paragraph, second
sentence: "All nonessential insulators shall be separated from any ESDS item by at least 300 mm".
Why is this Tailoring Statement Unnecessary? By not allowing nonessential insulators inside
EPAs, the ANSI/ESD S20.20 requirement to ensure all nonessential insulators are separated from
ESDS items by 300 mm is met. As a result, no tailoring statement is required.
Example 3
Tailoring Statement: The lower point to ground limit for worksurfaces used within the EPAs is
greater than 1.0 x 10
5
ohms instead of 0 ohms as required.
ANSI/ESD S20.20 Requirement Affected: Table 3, product qualification and compliance
verification 'point to groundable point' and 'point to ground' minimum resistance limit of 0 ohms as
tested using ANSI/ESD STM4.1 and ESD TR53, respectively. Also, in Sections 7.3 (product
qualification plan) and 7.4 (compliance verification plan), the required test limits provided in Table 3
shall be met.
Why is this Tailoring Statement Unnecessary? The lower limit established is within the limits of
ANSI/ESD S20.20. Since it is within the limits, tailoring is not required. This lower limit will be the
requirement of this facility.
ANSI/ESD S20.20-2021
16
(This annex is not part of ESD Association Standard ANSI/ESD S20.20-2021)
ANNEX D (INFORMATIVE) RELATED DOCUMENTS
The following documents are listed for further reference. Some documents may be canceled.
However, this listing provides a reference of documents reviewed during the preparation of this
standard.
Military / U.S. Government
MIL-STD-3010, Federal Test Method Standard
MIL-PRF-81705, Barrier Materials, Flexible, Electrostatic Discharge Protective, Heat-Sealable
MIL-PRF-38534, Performance Specification: Hybrid Microcircuits, General Specification
MIL-PRF-38535, Performance Specification: Integrated Circuits (Microcircuits) Manufacturing,
General Specification
MIL-STD-883-3 Method 3015, Test method standard for microcircuits
MIL-STD-750-1 Method 1020, Test methods for semiconductor devices
MIL-PRF-19500, Semiconductor Devices, General Specification
MIL-STD-1686, Electrostatic Discharge Control Program for Protection of Electrical and Electronic
Parts, Assemblies and Equipment (Excluding Electrically Initiated Explosive Devices) This
standard has been canceled.
MIL-HDBK-263, Electrostatic Discharge Control Handbook for Protection of Electrical and
Electronic Parts, Assemblies, and Equipment (Excluding Electrically-Initiated Explosive Devices)
This handbook has been canceled.
MIL-M-38510, General Specification for Military Microcircuits - This standard is inactive.
MIL-DTL-82646, Plastic Film, Conductive, Heat Sealable, Flexible
MIL-PRF-87893, Workstations, Electrostatic Discharge (ESD) Control
MIL-STD-129, Marking for Shipment and Storage
MIL-STD-1285, Marking of Electrical and Electronic Parts
KSC-MMA-1985-79, Standard Test Method for Evaluating Triboelectric Charge Generation and
Decay
MIL-HDBK-103, List of Standard Microcircuit Drawings
Supplemental Information Sheet for Electronic QML-19500
Industry Standards
ANSI/IEEE-STD-142, IEEE Green Book (IEEE Recommended Practice for Grounding of Industrial
and Commercial Power Systems)
ANSI/ESD SP5.0, ESD Association Standard Practice for Electrostatic Discharge Sensitivity
Testing Reporting ESD Withstand Levels on Datasheets
ANSI/ESDA/JEDEC JS-001, ESDA/JEDEC Joint Standard for Electrostatic Discharge Sensitivity
Testing Human Body Model (HBM) Component Level
ANSI/ESDA/JEDEC JS-002, ESDA/JEDEC Joint Standard for Electrostatic Discharge Sensitivity
Testing Charged Device Model (CDM) Device Level
ESD SP5.2, ESD Association Standard Practice for Electrostatic Discharge Sensitivity Testing -
Machine Model (MM) Component Level
ANSI/ESD SP10.1, ESD Association Standard Practice for the Protection of Electrostatic
Discharge Susceptible Items Automated Handling Equipment (AHE)
ANSI/ESD STM15.1, ESD Association Standard Test Method for the Protection of Electrostatic
Discharge Susceptible Items Methods for Resistance Measurement of Gloves and Finger Cots
ANSI/ESD S20.20-2021
17
ANSI/ESD SP17.1, ESD Standard Practice for the Protection of Electrostatic Discharge
Susceptible Items Process Assessment Techniques
ESD TR20.20, ESD Association Technical Report Handbook for the Development of an
Electrostatic Discharge Control Program for the Protection of Electronic Parts, Assemblies, and
Equipment
JESD625, Requirements for Handling Electrostatic-Discharge-Sensitive (ESDS) Devices
IPC/JEDEC J-STD-033, Handling, Packing, Shipping and Use of Moisture Reflow, and Process
Sensitive Devices
TR3.0-02-05, Selection and Acceptance of Air Ionizers
ESDSIL, Reliability Analysis Center (RAC) ESD Sensitive Items List
JESD471, Symbol and Label for Electrostatic Sensitive Devices
IEC 61340-5-1, Protection of Electronic Devices from Electrostatic Phenomena General
Requirements
VZAP, Electrostatic Discharge Susceptibility Data
ISO 9001, Quality Management Systems Requirements