2 Assembly Instructions "Long Board Option" SIPLACE HS-60 / D4 HS-60 / D4 "Long Board Option" 05/2007 Edition 38 : Connect the air hose to the air distr ibutor connector of a lif ting table using the …

HS-60 / D4 "Long Board Option" 2 Assembly Instructions "Long Board Option" SIPLACE HS-60 / D4
05/2007 Edition
37
2
: Plug the connector into slot X35 on the conversion board in the assembly trough.
2
X 35

2 Assembly Instructions "Long Board Option" SIPLACE HS-60 / D4 HS-60 / D4 "Long Board Option"
05/2007 Edition
38
: Connect the air hose to the air distributor connector of a lifting table using the preassembled
T-piece.
2
2
Only for PCBs between 50 and 110 mm: 2
: Remove the stopper unit between the conveyor side walls.
: Disconnect the cables.
: Remove the screws from the mount for the stopper unit.
2
before
after

HS-60 / D4 "Long Board Option" 2 Assembly Instructions "Long Board Option" SIPLACE HS-60 / D4
05/2007 Edition
39
The PCB lengths that can be set are: 610 mm, 580 mm, 550 mm and 515 mm. 2
2
2
: Switch the placement machine on at the main switch.
2
2
640 mm (272 mm)
670 mm (302 mm)
610 mm (242 mm)
510 mm (142 mm)
Stopper positions (the figure in brackets is the offset from the original stopper)