00193854-0402_AI_LBO_HS60-D4_DE+EN.pdf - 第39页
HS-60 / D4 "Lo ng Board Option" 2 Assembly Instructions "Long Board Option" SIPLACE HS-60 / D4 05/2007 Edition 39 The PCB lengths that can be set are: 610 mm, 580 mm, 550 mm and 515 mm. 2 2 2 : Switch…

2 Assembly Instructions "Long Board Option" SIPLACE HS-60 / D4 HS-60 / D4 "Long Board Option"
05/2007 Edition
38
: Connect the air hose to the air distributor connector of a lifting table using the preassembled
T-piece.
2
2
Only for PCBs between 50 and 110 mm: 2
: Remove the stopper unit between the conveyor side walls.
: Disconnect the cables.
: Remove the screws from the mount for the stopper unit.
2
before
after

HS-60 / D4 "Long Board Option" 2 Assembly Instructions "Long Board Option" SIPLACE HS-60 / D4
05/2007 Edition
39
The PCB lengths that can be set are: 610 mm, 580 mm, 550 mm and 515 mm. 2
2
2
: Switch the placement machine on at the main switch.
2
2
640 mm (272 mm)
670 mm (302 mm)
610 mm (242 mm)
510 mm (142 mm)
Stopper positions (the figure in brackets is the offset from the original stopper)

2 Assembly Instructions "Long Board Option" SIPLACE HS-60 / D4 HS-60 / D4 "Long Board Option"
05/2007 Edition
40
2.5 Software
2.5.1 SITEST
: Switch to the SITEST program.
: Select “Conveyor” –> “PCB conveyor”.
: Change the transport mode: Select “Long PCB with additional stopper” and confirm your sel-
ection.
: Start the station software.
2.5.2 Line computer
: Load the options from the CD-ROM.
: In the station configuration / component editor, activate “Long PCB” under PCB conveyor.
2