    SMT Softwa re Engineering Group IM Operations Y AMAHA MOT OR CO., L TD MD OC-SOFT50056  5/17  T able 3.1 R AS Setting Item Content 1) C/R +5V DC P ower Fail Check (Initial value: Use) In the case of “Us e”, if…

100%1 / 17
SMT Software Engineering Group
IM Operations
YAMAHA MOTOR CO., LTD
MDOC-SOFT50056
4/17
"Use" or "Not Use" can be set by each monitoring item on [RAS Setting] screen in Fig3.2.
When UPS is connected, the start time of the battery use can be updated by tapping the
[Replace Battery] button after the battery is exchanged.
Details of a set each item are as shown in Table 3.1.
It is necessary to restart the machine to do these settings effectively.
Fig 3.2 [RAS Setting] screen
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
12)
13)
14)
SMT Software Engineering Group
IM Operations
YAMAHA MOTOR CO., LTD
MDOC-SOFT50056
5/17
Table 3.1 RAS Setting
Item Content
1) C/R +5V DC Power
Fail Check
(Initial value: Use)
In the case of “Use”, if the +5V DC Power Fail signal is detected, the
Es404 error message (refer to 4.1.1) is displayed, and it becomes
the emergency stop condition. If the machine isn't restarted, the
restoration of the servo is impossible.
In the case of “Not Use”, the +5V DC Power Fail signal is ignored.
2) C/R +12V DC Power
Fail Check
(Initial value: Use)
In the case of “Use”, if the +12V DC Power Fail signal is detected,
the Es405 error message (refer to 4.1.2) is displayed, and it
becomes the emergency stop condition. If the machine isn't
restarted, the restoration of the servo is impossible.
In the case of “Not Use”, the +12V DC Power Fail signal is ignored.
3) C/R +3.3V DC Power
Fail Check
(Initial value: Use)
In the case of Use”, if the +3.3V DC Power Fail signal is detected,
the Es406 error message (refer to 4.1.3) is displayed, and it doesn't
become the emergency stop condition. The restoration of the servo
is possible.
In the case of “Not Use”, the +3.3V DC Power Fail signal is ignored.
4) C/R Fan1 Alarm
Check
(Initial value: Use)
In the case of “Use”, When the C/R Fan1 Alarm signal is detected,
- In YG300, the Es407 error message (refer to 4.1.4) is displayed,
and it doesn't become the emergency stop condition. The restoration
of the servo is possible. (Even if one of the fans stops, the machine
doesn't become the emergency stop condition because YG300 has
two fans in one C/R.)
- In excluding YG300, the Es411 error message (refer to 4.1.4) is
displayed, and it becomes the emergency stop condition. If the
machine isn't restarted, the restoration of the servo is impossible.
- In all models, If both the C/R Fan1 Alarm signal and the C/R Fan2
Alarm signal are detected, the Es410 error message (refer to 4.1.6)
is displayed, and it becomes the emergency stop condition. If the
machine isn't restarted, the restoration of the servo is impossible.
In the case of “Not Use”, the C/R Fan1 Alarm signal is ignored.
SMT Software Engineering Group
IM Operations
YAMAHA MOTOR CO., LTD
MDOC-SOFT50056
6/17
Item Content
5) C/R Fan2 Alarm
Check
(Initial value: Use)
In the case of “Use”, When the C/R Fan2 Alarm signal is detected,
- In YG300, the Es408 error message (refer to 4.1.5) is displayed,
and it doesn't become the emergency stop condition. The restoration
of the servo is possible. (Even if one of the fans stops, the machine
doesn't become the emergency stop condition because YG300 has
two fans in one C/R.)
- In excluding YG300, the Es412 error message (refer to 4.1.5) is
displayed, and it becomes the emergency stop condition. If the
machine isn't restarted, the restoration of the servo is impossible.
- In all models, If both the C/R Fan1 Alarm signal and the C/R Fan2
Alarm signal are detected, the Es410 error message (refer to 4.1.6)
is displayed, and it becomes the emergency stop condition. If the
machine isn't restarted, the restoration of the servo is impossible.
In the case of “Not Use”, the C/R Fan2 Alarm signal is ignored.
6) C/R Temp Error Check
(Initial value: Use)
In the case of “Use”, if the C/R Temp Error signal is detected, the
Es409 error message (refer to 4.1.7) is displayed, and it becomes
the emergency stop condition. If the machine isn't restarted, the
restoration of the servo is impossible.
In the case of “Not Use”, the C/R Temp Error signal is ignored.
7) SRV Fan Alarm Check
(Initial value: Use)
(This item is not displayed in YG300)
In the case of “Use”, if the SRV Fan Alarm signal is detected, the
Es413 error message (refer to 4.1.8) is displayed, and it becomes
the emergency stop condition. If the machine isn't restarted, the
restoration of the servo is impossible.
In the case of “Not Use”, the SRV Fan Alarm signal is ignored.