Table 3.1 RAS Setting
Item Content
1) C/R +5V DC Power
Fail Check
(Initial value: Use)
In the case of “Use”, if the +5V DC Power Fail signal is detected, the
Es404 error message (refer to 4.1.1) is displayed, and it becomes
the emergency stop condition. If the machine isn't restarted, the
restoration of the servo is impossible.
In the case of “Not Use”, the +5V DC Power Fail signal is ignored.
2) C/R +12V DC Power
Fail Check
(Initial value: Use)
In the case of “Use”, if the +12V DC Power Fail signal is detected,
the Es405 error message (refer to 4.1.2) is displayed, and it
becomes the emergency stop condition. If the machine isn't
restarted, the restoration of the servo is impossible.
In the case of “Not Use”, the +12V DC Power Fail signal is ignored.
3) C/R +3.3V DC Power
Fail Check
(Initial value: Use)
In the case of “Use”, if the +3.3V DC Power Fail signal is detected,
the Es406 error message (refer to 4.1.3) is displayed, and it doesn't
become the emergency stop condition. The restoration of the servo
is possible.
In the case of “Not Use”, the +3.3V DC Power Fail signal is ignored.
4) C/R Fan1 Alarm
Check
(Initial value: Use)
In the case of “Use”, When the C/R Fan1 Alarm signal is detected,
- In YG300, the Es407 error message (refer to 4.1.4) is displayed,
and it doesn't become the emergency stop condition. The restoration
of the servo is possible. (Even if one of the fans stops, the machine
doesn't become the emergency stop condition because YG300 has
two fans in one C/R.)
- In excluding YG300, the Es411 error message (refer to 4.1.4) is
displayed, and it becomes the emergency stop condition. If the
machine isn't restarted, the restoration of the servo is impossible.
- In all models, If both the C/R Fan1 Alarm signal and the C/R Fan2
Alarm signal are detected, the Es410 error message (refer to 4.1.6)
is displayed, and it becomes the emergency stop condition. If the
machine isn't restarted, the restoration of the servo is impossible.
In the case of “Not Use”, the C/R Fan1 Alarm signal is ignored.

SMT Software Engineering Group
IM Operations
YAMAHA MOTOR CO., LTD
MDOC-SOFT50056
6/17
Item Content
5) C/R Fan2 Alarm
Check
(Initial value: Use)
In the case of “Use”, When the C/R Fan2 Alarm signal is detected,
- In YG300, the Es408 error message (refer to 4.1.5) is displayed,
and it doesn't become the emergency stop condition. The restoration
of the servo is possible. (Even if one of the fans stops, the machine
doesn't become the emergency stop condition because YG300 has
two fans in one C/R.)
- In excluding YG300, the Es412 error message (refer to 4.1.5) is
displayed, and it becomes the emergency stop condition. If the
machine isn't restarted, the restoration of the servo is impossible.
- In all models, If both the C/R Fan1 Alarm signal and the C/R Fan2
Alarm signal are detected, the Es410 error message (refer to 4.1.6)
is displayed, and it becomes the emergency stop condition. If the
machine isn't restarted, the restoration of the servo is impossible.
In the case of “Not Use”, the C/R Fan2 Alarm signal is ignored.
6) C/R Temp Error Check
(Initial value: Use)
In the case of “Use”, if the C/R Temp Error signal is detected, the
Es409 error message (refer to 4.1.7) is displayed, and it becomes
the emergency stop condition. If the machine isn't restarted, the
restoration of the servo is impossible.
In the case of “Not Use”, the C/R Temp Error signal is ignored.
7) SRV Fan Alarm Check
(Initial value: Use)
(This item is not displayed in YG300)
In the case of “Use”, if the SRV Fan Alarm signal is detected, the
Es413 error message (refer to 4.1.8) is displayed, and it becomes
the emergency stop condition. If the machine isn't restarted, the
restoration of the servo is impossible.
In the case of “Not Use”, the SRV Fan Alarm signal is ignored.

SMT Software Engineering Group
IM Operations
YAMAHA MOTOR CO., LTD
MDOC-SOFT50056
7/17
Item Content
8) UPS Power Fail
Check
(When UPS is unconnected, it is invalid.)
In the case of “Use”, if the UPS Power Fail signal is detected, the
Ea2848 error message (refer to 4.1.9) is displayed, and it becomes
the emergency stop condition. The countdown begins at the time set
at the UPS Backup Time. The machine cannot be operated during
the countdown. The shutdown begins when the countdown ended or
the error clear button is clicked. The board data etc. under the edit
are not preserved.
In the case of “Not Use”, the system of the machine works as long as
the UPS battery is enough even if the power failure occurs. (If the
machine isn't restarted, the restoration of the servo is impossible)
However, there is a possibility of destroying the user data if the
machine is not shut down manually because the machine is not shut
down automatically.
9) UPS Battery Low
Check
(When UPS is unconnected, it is invalid.)
In the case of “Use”, if the UPS Battery Low signal is detected, the
Ea2847 error message (refer to 4.1.11) is displayed, and The
shutdown begins immediately even during the countdown.
In the case of “Not Use”, the machine is not shut down immediately.
10) UPS Active
(It is impossible to change because it is set in the factory.)
"Active" means when optional UPS is used, and other than that, it
becomes "Not Active". However, UPS that can be used here is
limited to the one specified by our company.
11) UPS Backup Time
(It is impossible to change because it is set in the factory.)
(When UPS is unconnected, it is invalid.)
If a power failure occurs when UPS is connected, UPS supplies
electric power during this setting time. The machine can continue the
auto-running if the failure is recovered within this setting time. If the
power failure continues more than this setting time, the machine is
shut down automatically.
While UPS is working, keyboard or mouse can work but the
auto-running of the machine or operation of axis etc, cannot work.
Default value is 60 seconds.