11 Y - A X I S lo ca t i on o f h e xa g on s o ck e t bol ts

100%1 / 17
10
location of grease nipple
Step5. feed the grease
2.2 Y-AXIS Clean And Lubrication
Step1. Loosen hexagon socket bolts by the hexagon socket bolt wrench and then take off
the Y-AXIS cover.
11
Y-AXIS
location of hexagon socket bolts
12
location of hexagon socket bolts
Step2. Use a clean fabric to remove original grease on the ball screw and inside the linear
module.
Step3. Use the specified small grease pump to feed specified grease from the grease
nipple.