TR7500_Maintenance_en.pdf - 第9页
8 2 . 1 X- Y T a b l e C l ea n And Lu b r i cat ion S t e p 1 . P u s h t h e X - AX I S an d Y - A X I S t o t h e r i gh t m o s t a n d r e a r m o s t s i d e S t e p 2 . L o o s en h e x ag o n s o c k e t bo l t s…

7
2 Quarter Maintenance
l In order not to damage the mechanical units and to prolong the lifespan of the mechanical
units, use the grease pump and grease specified by TRI when maintain the ball screw and
the linear guideway.
l specified grease
l specified small grease pump
l specified big grease pump

8
2.1 X-Y Table Clean And Lubrication
Step1. Push the X-AXIS and Y-AXIS to the rightmost and rearmost side
Step2. Loosen hexagon socket bolts by the hexagon socket bolt wrench and then take off
the X-AXIS cover.
location of hexagon socket bolts

9
location of hexagon socket bolts
Step3. Use a clean fabric to remove original grease on the ball screw and inside the linear
module.
Step4. Use the specified big grease pump to feed specified grease from the grease nipple.