Einsteckerlösung an BE Wagen S-F.pdf - 第25页
Special Design 2 Retrofit instructions for single plug soluti on for compo nent trolleys on S/F ma chines (item no.: 00166164-0 1) 10/2005 Edition 25 : Open the cover to the transformer by loosening the 2 nut s slightly …

2 Retrofit instructions for single plug solution for component trolleys on S/F machines (item no.: 00166164-01) Special Design
10/2005 Edition
24
2.6 Working on the component trolley
2.6.1 Removal
: Move the table in the top position out of the machine and disconnect the connectors and the
air supply.
: Shut down the station and switch it off.
: Remove the three cable ties from the U-shaped profile and one from beneath the table bed.
2
2
2
2
2
2
2
2

Special Design 2 Retrofit instructions for single plug solution for component trolleys on S/F machines (item no.: 00166164-01)
10/2005 Edition
25
: Open the cover to the transformer by loosening the 2 nuts slightly.
2
2
: Remove the cable gland and disconnect the power cable as follows:
- Cut off the brown wire approx. 8cm before the fuse.
- Disconnect the blue wire from the transformer terminal (2).
- Cut off the yellow-green wire on the top cable lug from the PE connection.
: Remove the cable.
2
2
2
2
2
2
2
2

2 Retrofit instructions for single plug solution for component trolleys on S/F machines (item no.: 00166164-01) Special Design
10/2005 Edition
26
: Open the front panel of the communication interface
2
2
: Remove connectors X4do, X7do and X9do from the board.
2
Connector