X service技术参数.pdf - 第43页
43 Technical Data Electrical Connection, Interfaces and Com- pressed Air Connect ion Compresse d air conn ection SMEMA / SIE MENS interface PC and LAN connec tion Powe r conn ect or 5 x 6 mm² cable with CEKON plug 5 x 32…

42
Technical Data
Electrical Ratings and
Compressed Air Supply
Electrical ratings
Supply voltage 3 x 208 VAC ± 5 %, 50/60 Hz (U.S.A. version)
3 x 230 VAC ± 5 %;50/60 Hz
3 x 380 VAC ± 5 %;50/60 Hz
3 x 400 VAC ± 5 %, 50/60 Hz (European version)
3 x 415 VAC ± 5 %;50/60 Hz
Fuses 3 x 32 A (3 x 208 VAC / 3 x 230 VAC)
3 x 16 A (3 x 380 VAC / 3 x 400 VAC / 3 x 415 VAC)
Total connected load 11.1 kVA
Total power 6.5 kW
Rated power consumption of the largest
consumer
X2: 8.4 A
X3: 8.9 A
X4: 9.4 A
Power failure max. 20 msec
Compressed air supply
Compressed air ratings
p
min
p
max
0.5 MPa = 5.0 bar
1.0 MPa = 10 bar
Compressed air connection 3/4"
Compressed air consumption with 4 tape
cutters and in relation to the placement
head configuration
SIPLACE X4
4 x C&P20 990 st. l/min.
4 x C&P12 or 4 x C&P6 800 st. l/min.
SIPLACE X3
3 x C&P12 or 3 x C&P6 700 st. l/min.
2 x C&P12/TH or 2 x C&P6/TH 550 st. l/min.
SIPLACE X2
C&P12/TH or C&P6/TH 350 st. l/min.
C&P12/C&P12 or C&P6/C&P6 450 st. l/min.
TH/TH 300 st. l/min.
Operating pressure 0.48 MPa ± 0.025 MPa (4.8 bar ± 0.25 bar)
Compressed air specification
Particle size 0.1 µm
Particle density 0.1 mg/m³
Maximum oil content (class 1) Particle density 0.01 mg/m³
Pressure dewpoint (class 4) Dewpoint + 3°

43
Technical Data
Electrical Connection, Interfaces and Com-
pressed Air Connection
Compressed air connectionSMEMA / SIEMENS interface
PC and LAN connection
Power connector
5 x 6 mm² cable with CEKON plug 5 x 32 A (3 x 208 VAC / 3 x 230 VAC)
5 x 4 mm² cable with CEKON plug 5 x 16 A (3 x 380 VAC / 3 x 400 VAC / 3 x 415 VAC)

44
Technical Data
Dimensions and Set-up Conditions
* The load per unit area calculation included an additional working space of 0.5 m on each side of the
machine, and an additional transport load of 300 kg (machine operator, etc).
Further data available on request
Length
with both extension kits
with one extension kit
with no extension kits
2380 mm
2103 mm
1826 mm
Width of the basic machine
X4 with docked CO changeover table (locations 1 + 4)
X4 with docked CO changeover table (locations 2 + 3)
X3 with docked CO changeover table (locations 1 + 4)
X3 with docked CO changeover table (locations 2 + 3)
X2 with docked CO changeover table (locations 1 + 4)
X2 with docked CO changeover table (locations 2 + 3)
incl. monitors
with keyboards
2815 mm
2815 mm
2815 mm
2395 mm
2395 mm
2395 mm
2766 mm
2804 mm
Weight
X4 (machine with component changeover table)
X4 (full configuration with feeder modules)
X3 (machine with component changeover table)
X3 (full configuration with feeder modules)
X2 (machine with component changeover table)
X2 (full configuration with feeder modules)
3880 kg
4255 kg
3790 kg
4171 kg
3705 kg
4086 kg
Footprint
X4, X3 and X2 6.70 m²
Load per unit area
*)
X4
X3
X2
6.30 kN/m²
6.20 kN/m²
6.10 kN/m²
Number of machine feet 6
Height of the machine with warning lamp max. 1863 mm
Machine ground clearance 120 mm (standard height)
240 mm (SMEMA height)
Maximum noise emissions 74 dB (A)
Room temperature between 15 °C and 35 °C
Atmospheric humidity 30 to 75 % (no higher than 45%
on average to prevent any possi-
bility of condensation on the ma-
chine)