QP341 351E规格书.pdf - 第11页

5. Feeder , Camera, and Nozzle Station Selection 5.1 Feeder T able Parts supply units can be selected as detailed below. Notes: The front supply unit on the QP-341E is fixed. MF: IP-series and QP-242E mechanical feeders …

100%1 / 34
4.2 Machine Configuration Examples
Examples of feeder, camera, and nozzle station combinations are shown below.
*1. Upper: QP-341E, Lower: QP-351E, MF: IP-series, QP-242E feeders; PF: QP-132E, NP-
series Power Feeders
*2. Refer to section 5.3 for details of nozzle station types.
The available options for each of the categories above (A - F) are detailed below.
Example
Options
A
N/A
✓✓
QP3S008
B
C
D
FE
Remarks
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
STU
Reject parts conveyor
Automatic tape cutter
Automatic tape cutter
Lead coplanarity check
Placing pressure control
Vacuum back-up pins
Parts confirmation sensor
Insertion control placing
Acryl covers (fence, safety doors)
Rear operation panel
Tray removal confirmation
Area sensor
Sliding side door cover
Roller conveyor
HELPS
Handy Terminal
Kitting Station
Mechanical feeders (BFC, IPC, MF)
Power Feeders
Stick feeder
Feeder stand
Feeder set-up jig
Tape splicer
: Available options (factory or onsite installation) N/A: Not applicable –: Pending
(for MFU, PFU)
(QP-341E-MM only)
October 1999
Under development
Under development
Under development
Under development
Specify with order
Specify with order
Specify with order
(#1) An MFU compatible with stick feeders can be used at the front of the machine if specially requested.
(#1)
(351E) (351E)
Example
Items
Rear
A
MFU-6E
N/A
LS
B
MFU-6E
MFU-6E
LS
LS
C
MFU-6E
MTU-9E
LS
LS
D
PFU-3E
PFU-3E
LS
LS
FE
PFU-3E
PFU-3E
LS
LS/CCD
LS
LS
BBBBBB
Feeder
Unit
Front
Rear
Camera
Nozzle station type
(*2)
Front (*1)
N/A
MF
MF
PF PF
PF
MFU-6E
PFU-3E
MTU-9E
– 7 – QP-341E-MM/QP-351-MM Specifications
Preliminary (January 10, 2000)
5. Feeder, Camera, and Nozzle Station Selection
5.1 Feeder Table
Parts supply units can be selected as detailed below.
Notes: The front supply unit on the QP-341E is fixed.
MF: IP-series and QP-242E mechanical feeders
PF: QP-132E and NP-series Power Feeders
A safety fence is attached during use of the MFU-6E, and IP-series/QP-242E
mechanical feeders.
Refer to the table below for the maximum number of feeders that can be set.
Notes: The fixed supply side feeder capacity is the same as for an MFU-6E or a PFU-3E.
Stick feeders for the MFU-6E can only be used on the rear side of the machine, unless
use at the front of the machine is specially requested.
The tape index lever on IPC-type feeders must be changed prior to use.
72 mm and wider Power Feeders, and stick feeders are under development for the
PFU-3E.
Tape feeders
Stick feeders
Max. feeders
8 mm (1P)
12 mm (1P)
16 mm (2P)
24 mm (2P)
32 mm (2P)
44 mm (3P)
56 mm (4P)
72 mm (5P)
88 mm (6P)
7 mm W 28 mm (2P)
25 mm W 48 mm (3P)
24
24
11
11
11
8
6
5
4
11
8
Type - 1
Type - 2
Remarks
Packaging sizeFeeder type
24 x 2
24
12
12
12
8
6
MFU-6E PFU-3E
(#1): 8 mm double channel feeder on the PFU.
#1
QP3S010
Front
Rear
QP-341E QP-351E
Fixed mechanical
feeder table (MF)
Fixed Power Feeder
table (PF)
MFU-6E
PFU-3E
MFU-6E
PFU-3E
MTU-8E
MTU-9E
No installation No installation
QPS3S042
– 8 – QP-341E-MM/QP-351-MM Specifications
Preliminary (January 10, 2000)
5.2 Camera Type Combinations
The above placing accuracy is achieved under Fuji’s specific conditions using a glass
board, glass parts, and PAM program.
(#1) Placing accuracy may vary depending on the camera and parts types. Placing accuracy for
parts with leads on all four sides is ±0.03 mm (3
σ
).
(#2) Special nozzles are available for parts of height between 10 and 25.4 mm.
(#3) To increase the range of parts that can be handled, an additional part inspection camera can
be attached at one or both sides of the machine.
1) Camera combinationLine-scan + CCD
2) Limitation (Rear side) Nozzle station B type only
(#4) 100 % detection of missing bumps on CSPs and BGAs.
Inspection results for CCGAs may be poor depending on the shape and detected light
reflected from the pins (cylinders).
CCGAs 1 x 1 mm to 50 x 74 mm can be handled. Testing is necessary for CCGAs of
42.5 x 42.5 mm and larger.
(#5) 100 % bump detection (except for white BGAs and CCGAs).
Orientation check for CSPs and BGAs.
Support for bump array parts from 1 x 1 mm to 55 x 74 mm.
(#6) Restrictions on part size may apply if parts are simultaneously picked up at all three
nozzles. Parts of up to 40 x 40 mm can be handled if the same part is picked up by all three
nozzles.
(#7) Supports the placement of parts with lengths of 74 mm to 150 mm.
The above specifications may be subject to change without notice.
Camera Type
Items
Placing accuracy (mm)
Max. placing height (mm)
Placing headVision system
Lighting
Camera type
Line-scan 2048
Min. lead pitch (mm)
Min. lead width (mm)
Part size (mm)
Min. space between leads (mm)
Adjustable frame function
Multiple image acquisition
or adjustable frame function
Line-Scan
3σ : ± 0.066 / ± 0.030
6σ : ± 0.132 / ± 0.060
CCD
10 (25.4)
Foreground and background
1608 (in. 0603) – 74 x 74 mm
0.24
3σ : ± 0.066
6σ : ± 0.132
CCD
Background
0603 (in. 0201) – 3216
QP3S011
___
___
___
___
___
(#1)
(#2)
(#4)
(#6)
(#5)
(#7)
(#3)
0.14
0.14
– 9 – QP-341E-MM/QP-351-MM Specifications
Preliminary (January 10, 2000)