277932_documentation.pdf - 第3页

3 2025/10 www.fes to.c om/catalogue/... 537716055 | | 13.10.2025 Solenoid c oil V A CN Datasheet General t echnical dat a - Solenoid coil s N for Armatur e tube 9 mm, with electrical c onne ction form A Electrical c onne…

100%1 / 18
2
www.festo.com/catalogue/... 2025/10
537716055 | | 13.10.2025
Solenoid coil VACN
Type code
001 Series
VACN Solenoid coil VACN
002 Solenoid coil type
H1 Solenoid coil H1 for armature tube 14 mm
N Solenoid coil N for armature tube 9 mm
003 Electrical connection
A1 Plug pattern type A, to EN 175301-803
K1 Cable
K11 Cable with insulating conduit connection
R3 Single plug M12 A-coded, according to EN 61076-2-101
R4 Single plug M12 A-coded, pin assignment according to DESINA
004 Nominal operating voltage
1 24 V DC
2A 110 V AC/50-60 Hz
3A 230 V AC/50-60 Hz
16B 120 V AC/60 Hz and 110V AC/50-60 Hz
005 Cable length [m]
0.5 0.5
10 10
006 EU certication
None
EX2 II 3GD
EX4 II 2GD
007 Certication
None
U4 Class1 Div1 to NEC 500
008 Type of ignition protection
None
A Intrinsically safe
M Encapsulation
N Non-sparking
3
2025/10 www.festo.com/catalogue/...
537716055 | | 13.10.2025
Solenoid coil VACN
Datasheet
General technical data - Solenoid coils N for Armature tube 9 mm, with electrical connection form A
Electrical connection Type A, To DIN EN 175301-803
Type of actuation Electric
Type of mounting Via knurled nut
Mounting position optional
Electrical data - Solenoid coils N for Armature tube 9 mm, with electrical connection form A
Nominal operating voltage 24 V DC 230 V AC/50-60 Hz 120 V AC/60 Hz and 110V AC/50-60 Hz
EU certication None II 3GD II 2GD None II 3GD None II 3GD
Characteristic coil data 24 V DC: 0.7 W 24 V DC: 2.1 W 230 V AC: 50 Hz,
pick-up power 6.2
VA, holding power
3.7 VA, 230 V AC:
60 Hz, pick-up pow-
er 4.9 VA, holding
power 2.9 VA
230 V AC: 50 Hz,
pick-up power 6.9
VA, holding power
4.1 VA, 230 V AC:
60 Hz, pick-up pow-
er 5.4 VA, holding
power 3.3 VA
110 V AC: 50 Hz,
pick-up power 5.2
VA, holding power
3.1 VA, 110 V AC:
60 Hz, pick-up pow-
er 4.2 VA, holding
power 2.5 VA
110 V AC: 50 Hz,
pick-up power 6.9
VA, holding power
4.1 VA, 110 V AC:
60 Hz, pick-up pow-
er 5.4 VA, holding
power 3.2 VA
Max. input voltage Ui 28 V
Max. input current Ii 115mA
Required current consumption 27mA
Eective internal capacitance
Ci
Negligibly low
Permissible voltage uctua-
tions
+/- 10% +/- 10%
Immunity to surge 4 kV 2.5 kV
Duty cycle 100%
Insulation material class F
Insulation material class of
enamelled wire
F H F H F H
Degree of protection IP65
Pollution degree 3 3
4
www.festo.com/catalogue/... 2025/10
537716055 | | 13.10.2025
Solenoid coil VACN
Datasheet
ATEX - Solenoid coils N for Armature tube 9 mm, with electrical connection form A
EU certication None II 3GD II 2GD
ATEX category gas II 3G II 2G
Explosion ignition protection
type for gas
Ex nA IIC T5/T4 X Gc Ex ia IIC/IIB T6/T4 Gb
ATEX category dust II 3D II 2D
Explosion ignition protection
type for dust
Ex tc IIIC T95°C/T105°C X Dc Ex tb IIIC T80°C/T130°C Db
Explosion ambient tempera-
ture
-20°C <= Ta <= +60°C T4, T130°C: -40°C <= Ta <= +85°C
T6, T80°C: -40°C <= Ta <= +50°C
Explosion protection certica-
tion outside the EU
EPL Dc (GB); EPL Gc (GB) EPL Db (BR); EPL Db (CN); EPL Db (GB); EPL Db (IEC-
EX); EPL Gb (BR); EPL Gb (CN); EPL Gb (GB); EPL Gb
(IECEx)
Certicate issuing authority DNV TAA000011J CCC 2021322307003993
DNV 15.0188
DNV TAA000011J
GYJ21.1326
IECEx PTB 15.0013
PTB 09 ATEX 2043
Materials - Solenoid coils N for Armature tube 9 mm, with electrical connection Form A
Material housing Polymer, Steel
Material winding Copper
Material electrical contact Brass
Note on materials RoHS-compliant
LABS (PWIS) conformity VDMA24364-B2-L
Operating and environmental conditions - Solenoid coils N for Armature tube 9 mm, with electrical connection form A
Nominal operating voltage 24 V DC 230 V AC/50-60 Hz 120 V AC/60 Hz and 110V AC/50-60 Hz
EU certication None II 3GD II 2GD None II 3GD None II 3GD
Ambient temperature -20 ... 60°C -20 ... 50°C -20 ... 60°C
Corrosion resistance class
CRC
1)
2 - Moderate corrosion stress
CE mark (see declaration of
conformity)
2)
To EU Explosion Protection Directive (ATEX) To EU Low Voltage
Directive
To EU Explosion Pro-
tection Directive
(ATEX)
To EU Low Voltage
Directive
To EU Explosion Pro-
tection Directive
(ATEX)
UKCA marking (see declaration
of conformity)
To UK EX instructions To UK regulations
for electrical equip-
ment
To UK EX instruc-
tions
To UK regulations
for electrical equip-
ment
To UK EX instruc-
tions
Maritime classication
3)
See certicate
1) More information www.festo.com/x/topic/kbk
2) More information www.festo.com/catalogue/... Support/Downloads.
3) More information www.festo.com/catalogue/... Support/Downloads.