00191457-02.pdf - 第18页
Retrofit instructions Nozzle changer SIPLACE H S-50 / HS-60 / D4 06/2006 Edition 18 2.3 Safety instructions W ARNING The safety instructio ns from the “Operational sa fety” chapter of the user ma nual and servicing in- s…
Retrofit instructions Nozzle changer SIPLACE HS-50 / HS-60 / D4
06/2006 Edition
17
2 Retrofit instructions:
Nozzle changer SIPLACE HS-50 /
HS-60 / D4
2.1 Parts required
2.1.1 SIPLACE HS-50 / HS-60
2
2.1.2 SIPLACE D4
2
2.2 Tools and consumables required
Set of hexagon socket spanners 2
Quantity Designation Item number
1 Set of nozzle changers for the HS-xx revolver head, consisting of: 00119160-xx
4 Nozzle changer for the HS-xx revolver head 00119161-xx
1 CAN I/O module 00329698-xx
4 Ejector device for the HS-xx nozzle changer 00341091-xx
4 Plug QSC-4H 00330249-xx
4 Y-adapter, single 00345245-xx
Quantity Designation Item number
1 Set of nozzle changers for the HS-xx revolver head, consisting of: 00119888-xx
4 Nozzle changer for D4 00119161-xx
1 CAN I/O module 00329698-xx
4 Ejector device for D4 03048803-xx
4 Plug QSC-4H 00330249-xx
4 Y-adapter, single 00345245-xx

Retrofit instructions Nozzle changer SIPLACE HS-50 / HS-60 / D4
06/2006 Edition
18
2.3 Safety instructions
WARNING
The safety instructions from the “Operational safety” chapter of the user manual and servicing in-
structions take precedence over these instructions. 2
The SIPLACE placement machines are supplied with mains voltage.
Consequently parts of these systems carry dangerous voltages! This voltage is present at certain
modules inside the machine base, even when the machine is switched off at the main power
switch.
Incorrect handling of the placement machine or touching live parts of the machine can result in
death or severe injury, and considerable damage to equipment.
BEFORE starting any work, shut down the operating system correctly, then switch the machine
OFF at the main power switch and disconnect from the main power supply. In addition, the com-
pressed air supply must be switched off at the compressed air unit's main valve in the machine
base and vented by actuating the needle valve on the compressed air unit.
There is DANGER for heart pacemaker wearers in the vicinity of the linear motors, as described
in detail in the "Special safety instructions for working in the vicinity of strong magnetic fields"
section of the user manual and service manual.
Always follow the accident prevention regulations, DIN or other standards and special safety
rules applicable in your country.
Pay attention to the information concerning residual voltages in the Operational Safety chapter.
Follow the ESD regulations as described in the operational safety section of the operating
instructions.
During the retrofit, always secure the machine to prevent access by other people and to prevent
it being switched on again. The procedure is described in the “Locking the machine…” section of
the user manual.
Working with the SITEST program further increases the risk of accident.
The SITEST program must only be used by authorized and trained personnel.
2
2.3.1 Definitions
2
Please note 2
2
2
2

Retrofit instructions Nozzle changer SIPLACE HS-50 / HS-60 / D4
06/2006 Edition
19
2.4 Position of nozzle changers and sector distribu-
tors
2
Fig. 2 - 1 Position of the nozzle changers and sector distributors
(1) Used tape guide channel
(2) Nozzle ejector device
(3) Location of the 1st nozzle changer
(4) Nozzle magazines
(5) Location of the 2nd nozzle changer
(6) Collecting container for ejected nozzles
(7) Distributor, sector 4
(8) Distributor, sector 1
(9) Opening for the connecting cable and compressed air line