circuit of HS60.pdf - 第171页

5 - 39 0036373 8-010 201ND 4 983 board, vacuum boa rd (2 sectors) (Sh. 1 of 2) 0036373 8-010 201ND 4 983 board, vacuum boa rd (2 sectors) (Sh. 2 of 2) C = ESD-L AB EL B = INSPECTION LABEL ON PRESSURE SENSO RS A = IDENTIF…

100%1 / 184
5 - 38
00362766-010101ND4 984 board, conversion board, lifting table
Stat.
01
Modified
04.04.01
Date
KD
Name
PC board
Dorfner
04.04.01
MCHN R/Tu
SIEMENS AG
ATD TD E
Date
Name
Component layout, component side
G32918 - N0032 - U201 - * - 17
Conversion board
00362766-010101ND4
PC board
Scale
1 : 1
1 -
Sheet
984
2-layer
A Assembly designation 11x13 (solder side)
B Inspection label (solder side)
Lifting table
1
2
3
6
2
3
4
6
2
3
5
6
1
2
3
6
2
3
4
6
1
2
3
4
5
6
10
Connector X1
Connector X2
Connector X3
Connector X4
Connector X5
Connector X6
Key
Track A
+24V
GND
Key
Track B
+24V
GND
Key
+24V
Limit switch
GND
GND
+24V
Valve "up"
Key
GND
+24V
Valve "down"
Key
+24V
Track A
Track B
Limit switch
Valve "up"
Valve "down"
GND
5 - 39
00363738-010201ND4 983 board, vacuum board (2 sectors) (Sh. 1 of 2)
00363738-010201ND4 983 board, vacuum board (2 sectors) (Sh. 2 of 2)
C = ESD-LABEL
B = INSPECTION LABEL ON PRESSURE SENSORS
A = IDENTIFICATION LABEL, LATERAL TO P1-P4
Status
Note
Date
Name
Date
Name
M 1:1
4-layer PCB
Placement diagram component side
PCB 983
VACUUM BOARD (2 MEAS. RANGES)
05.04.01
KLOSE
Assembly
X10 gantry head distributor 00344487
Connector
X1
Sheet
05.04.01
KLOSE
State
Note
Date
Name
Name
Date
M 1:1
4-layer PCB
Placement diagram soldering side
PCB 983
VACUUM BOARD (2 MEAS. RANGES)
Sheet
5 - 40
00367074-010101ND4 Adjustment unit 2 / placement circuit
Mounting diagram, component side
Adjustment drive 2
Placement circuit
00367074-010101ND4
1
1
SIEMENS AG
06.11.2001
06.11.200101
Stat. Modified Date Name
Date
Name
Sheet
Sh.
U1
X1
R5
R6
Pin 1
X1
A1
B1, B2
1
10
R
1
X2
C3
X3
R4
U2
X5
X4
R2
R3
+5.0mm
-5.0mm
50.0mm
340.0mm
B1, B2:
A1:
C2
U3
R7
C4
C5
C6
Cable, 05-1630-5
X18 stepping motor board 00344488
Assembly
Connector
X1
on the cable
Readable, when X1 is on the right.
50mm distance from cable end.
AFO and WIP inspection labels.
Label position:
On the back.
Identification label,
readable, when X1 is on the left.
May be printed