ACF-Bonding.pdf - 第12页

Panel R epair F actory India pvt. Ltd. 12 C OF CHE CKING WITH MICR OSC OPE COF T r acks Digit al Micr oscope

100%1 / 24
Panel Repair Factory India pvt. Ltd. 11
COF CLEANING WITH ACETON
Dip cotton buds in acetone
& COF clean only vertical
direction
Fold cloth on stick & dip in
acetone and COF clean
only vertical direction
Acetone
Panel Repair Factory India pvt. Ltd. 12
COF CHECKING WITH MICROSCOPE
COF
Tracks
Digital
Microscope
ACF is necessary for COF bonding, the ACF will connect COF with
Glass and PCB. Should choose the correct ACF before bonding. The
ACF for Glass side and PCB side is different.
AC-7206U-18 1.5(W)X50(L)M
for glass side
AC-2056R-35 2.0(W)X50(L)M
for PCB side
ACF should be stored in low temperature 5(like fridge),
Please check the valid date of use written on the ACF label.
ACF should not be used when expired.
Put ACF back to the fridge after every day work finished.
ACF TAPE MODEL
13 Panel Repair Factory India pvt. Ltd.