ACF-Bonding.pdf - 第24页
Panel R epair F actory India pvt. Ltd. 24 CHE CK P ANEL AFTER BONDING

Panel Repair Factory India pvt. Ltd. 22
PUT SILICON
TAPE ON COF
PRESS
MANUAL
ALIGNMENTS
WITCH
DO PREBOND
UP TO 80 °
TEMP
HEAD PRESS
ON & STOP
MANUAL
ALIGNMENT
MATCH ITO & COF
TRACK PROPERLY
DURING
PREBOND TIME
STOP
PREBONING
WITHIN 10 TO
15 SEC
PRESS GLASS
BONDING
SWITCH
VACCUME
SWITCH OFF &
REMOVE GLAAS
FROM MACHINE
NOW DO PCB
SIDE
BONDING
STEP BY STEP BODING PROCESS

Testing After Bonding
After bonding, do a testing with the screen, make sure the fault
was repaired.
If not repaired, analyze the reason and repair again. Usually
bright line means short circuit; dark line means off circuit.
After replaced
COF fault
removed
23 Panel Repair Factory India pvt. Ltd.

Panel Repair Factory India pvt. Ltd. 24
CHECK PANEL AFTER BONDING