3 Replacing the Y trailing cable vacuum assembly
20 Assembly Instructions E by SIPLACE Replacing the X and Y Trailing Cable 04/2018
► Unplug all pneumatic connections to the gantry.
► Unplug all electrical connections from the trailing cable to the X and Y trailing cable interface.
► Unplug all pneumatic connections to the valve joint.
► Unplug the electrical connections to the trailing cable interface.
Fig.16: Bracket on top of trailing cable
► Loosen the two screws and nuts
fastening the trailing cable chain to the
gantry. These screws (hexagonal bolts
[03023606-xx]) must be resealed with
Loctite 241 when fitted again.
Fig.17: Removing trailing cable
► Loosen the four screws fastening the
bracket (1) on the top of trailing cable.
► Remove the trailing cable from the
machine.
Installation
► Follow the removal instructions in reverse order for installation. Also observe the following
instructions:
CAUTION
Installation instructions
Fix the screws fastening the trailing cable chain to the gantry and to the cover with Loctite
241.

Item no.: 00198609-01 ASM Assembly Systems Singapore Pte Ltd