Seagate IronWolf Pro SAT A Pro duct Manua l, Rev B 11 www.seagate.com 2.5.1 P ower co nsumption P ower requir ement s fo r the drives are listed in T able6, DC power req ui rements (24/20/16/12TB models) . T y p i cal p…

Seagate IronWolf Pro SATA Product Manual, Rev B 10
www.seagate.com
2.3 Recording and interface technology
2.4 Start/stop times
Power-on to Ready time is based on typical operating conditions, default full current spin-up profile, and clean
shutdown prior to measurement. To ensure a clean shutdown, a Flush Cache, Standby, or Standby Immediate
command must be completed before removal of interface power.
NOTE An unexpected power loss event and/or spin up at cold or hot temperature
extremes may cause the drive to exceed the typical time to ready by 5 seconds.
Extended time to ready is dependent on cache state and environmental
conditions prior to the unexpected power loss and during the subsequent
power on.
2.5 Power specifications
The drive receives DC power (+5V or +12V) through a native SATA power connector. Figure 3, Attaching SATA cabling,
on page 21.
Table 4 - Recording and interface technology
Interface Serial ATA (SATA)
Recording method Perpendicular
Recording density, KBPI (Kb/in max) 2552
Track density, KTPI (ktracks/in avg) 537
Areal density (Gb/in
2
avg)
1260
Spindle speed (RPM) (± 0.2%) 7200
Internal data transfer rate (Mb/s max) 2951
Sustained data transfer rate (MB/s max)
24/20/16/12TB 285
I/O data-transfer rate (MB/s max) 600 (Ultra DMA mode 5)
Table 5 - Start/stop times
Interface Time
Power-on to Ready (sec) (typ/max) 25/30
Standby to Ready (sec) (typ/max) 25/30
Ready to Spindle Stop (sec) (max) 20

Seagate IronWolf Pro SATA Product Manual, Rev B 11
www.seagate.com
2.5.1 Power consumption
Power requirements for the drives are listed in Table6, DC power requirements (24/20/16/12TB models). Typical power
measurements are based on an average of drives tested, under nominal conditions, using 5.0V and 12.0V input
voltage at 35°C ambient temperature.
NOTE During periods of drive idle, some offline activity may occur according to the
SMART specification, which may increase acoustic and power to operational
levels.
Table 6 - DC power requirements (24/20/16/12TB models)
Workload Mode 6.0Gb mode
Voltage +5V +12V Watts
Regulation ± 5% ± 10% Total
Avg Idle Current * 0.328 0.378 6.19
Advanced Idle Current *
Idle_A 0.337 0.375 6.20
Idle_B 0.260 0.227 4.03
Idle_C 0.256 0.143 3.00
Standby 0.206 0.01 1.16
Maximum Start Current
DC (peak DC) 0.868 1.69
AC (Peak DC) 1.06 1.96
Delayed motor start (max) DC 0.585 0.812
Operating current (random read 4K16Q):
Typical DC 0.395 0.582 8.98
Maximum DC 0.401 0.587 9.07
Maximum DC (peak) 1.012 2.03
Operating current (random write 4K16Q)
Typical DC 0.409 0.556 8.75
Maximum DC 0.414 0.561 8.83
Maximum DC (peak) 1.023 1.812
Operating current (sequential read 64K16Q)
Typical DC 0.78 0.364 8.3
Maximum DC 0.792 0.367 8.4
Maximum DC (peak) 1.042 2.021
Operating current (sequential write 64K16Q)
Typical DC 0.848 0.359 8.58
Maximum DC 0.858 0.362 8.67
Maximum DC (peak) 1.062 1.622

Seagate IronWolf Pro SATA Product Manual, Rev B 12
www.seagate.com
2.5.1.1 Typical current profiles
Figure 1. DC power requirements (24TB models)
2.5.2 Conducted noise
Noise is specified as a periodic and random distribution of frequencies covering a band from DC to 10 MHz. Maximum
allowed noise values given below are peak-to-peak measurements and apply at the drive power connector.
2.5.3 Voltage tolerance
Voltage tolerance (including noise):
+5v = 250 mV pp from 100 Hz to 20 MHz
+12v =
800 mV pp from 100 Hz to 8 KHz
450 mV pp from 8 KHz to 20 KHz
250 mV pp from 20 KHz to 5 MHz
+5v = ± 5%
+12v = ± 10%