Seagate IronWolf Pro SAT A Pro duct Manua l, Rev B 25 www.seagate.com Notes: 1. All pins are in a s ingle r ow, wi th a 1.27mm (0 .050”) pitch. 2. The comments on the mating s equence app ly to the case of b a ckplane b …

Seagate IronWolf Pro SATA Product Manual, Rev B 24
www.seagate.com
4. Serial ATA (SATA) interface
These drives use the industry-standard Serial ATA interface that supports FIS data transfers. It supports ATA
programmed input/output (PIO) modes 0–4; multiword DMA modes 0–2, and Ultra DMA modes 0–6.
For detailed information about the Serial ATA interface, refer to the “Serial ATA: High Speed Serialized AT Attachment”
specification.
4.1 Hot-Plug compatibility
Seagate IronWolf Pro SATA drives incorporate connectors which enable users to hot plug these drives in accordance
with the Serial ATA Revision 3.3 specification. This specification can be downloaded from www.serialata.org.
4.2 Serial ATA device plug connector pin definitions
Table21, Serial ATA connector pin definitions summarizes the signals on the Serial ATA interface and power connectors.
Caution
The drive motor must come to a complete stop (Ready to Spindle Stop time indicated in Section 2.4 Start/stop
times) prior to changing the plane of operation. This time is required to ensure data integrity.
Table 21 - Serial ATA connector pin definitions
Segment Pin Function Definition
Signal S1 Ground 2nd mate
S2 A+ Differential signal pair A from Phy
S3 A-
S4 Ground 2nd mate
S5 B- Differential signal pair B from Phy
S6 B+
S7 Ground 2nd mate
Key and spacing separate signal and power segments

Seagate IronWolf Pro SATA Product Manual, Rev B 25
www.seagate.com
Notes:
1. All pins are in a single row, with a 1.27mm (0.050”) pitch.
2. The comments on the mating sequence apply to the case of backplane blindmate connector only. In this case, the
mating sequences are:
— the ground pins P4 and P12.
— the pre-charge power pins and the other ground pins.
— the signal pins and the rest of the power pins.
3. There are three power pins for each voltage. One pin from each voltage is used for pre-charge when installed in a
blind-mate backplane configuration.
4. All used voltage pins (V
x) must be terminated.
4.3 Supported ATA commands
The following table lists Serial ATA standard commands that the drive supports. For a detailed description of the ATA
commands, refer to the Serial ATA: High Speed Serialized AT Attachment specification. See Section 4.3.5 SMART
commands for details and subcommands used in the SMART implementation.
Power P1 V33 Not Used (P1 and P2 tied internally)
P2 V33 Not Used (P1 and P2 tied internally)
P3 PWRDIS Enter/Exit Power Disable (option)
P4 Ground 1st mate
P5 Ground 2nd mate
P6 Ground 2nd mate
P7 V5 5V power, pre-charge, 2nd mate
P8 V5 5V power
P9 V5 5V power
P10 Ground 2nd mate
P11 Ground or LED signal If grounded, drive does not use deferred spin
P12 Ground 1st mate
P13 V12 12V power, pre-charge, 2nd mate
P14 V12 12V power
P15 V12 12V power
Table 22 - Supported ATA commands
Command name Command code (in hex)
Accessible Max Address Configuration
Get Native Max Address Ext 78H / 0000H
Set Accessible Max Address Ext 78H / 0001H
Freeze Accessible Max Address Ext 78H / 0002H
Check Power Mode E5H
Configure Stream 51H
Table 21 - Serial ATA connector pin definitions (continued)
Segment Pin Function Definition

Seagate IronWolf Pro SATA Product Manual, Rev B 26
www.seagate.com
Download Microcode 92H
Execute Device Diagnostics 90H
Flush Cache E7H
Flush Cache Extended EAH
Get Physical Element Status 12H
Identify Device ECH
Idle E3H
Idle Immediate E1H
Read Buffer E4H
Read DMA C8H
Read DMA Extended 25H
Read FPDMA Queued 60H
Read Log DMA Ext 47H
Read Log Ext 2FH
Read Multiple C4H
Read Multiple Extended 29H
Read Sectors 20H
Read Sectors Extended 24H
Read Stream DMA Ext 2AH
Read Verify Sectors 40H
Read Verify Sectors Extended 42H
Receive FPDMA Queued 65H
Request Sense Data Ext 0BH
Remove Element And Truncate 7CH
Restore Elements And Rebuild 7DH
Sanitize Device - Crypto Scramble B4H / 0011H (SED and ISE drives only)
Sanitize Device - Overwrite Ext B4H / 0014H
Sanitize Device - Freeze Lock Ext B4H / 0020H
Sanitize Device - Status Ext B4H / 0000H
Security Disable Password F6H
Security Erase Prepare F3H
Security Erase Unit F4H
Security Freeze F5H
Security Set Password F1H
Security Unlock F2H
Seek 70H
Send FPDMA Queued 64H
Set Date & Time Ext 77H
Set Features EFH
Set Multiple Mode C6H
Table 22 - Supported ATA commands
Command name Command code (in hex)