Seagate_IronWolf_Pro_SATA_Product_Manual_24-20-16-12TB_206815300B.pdf - 第13页

Seagate IronWolf Pro SAT A Pro duct Manua l, Rev B 13 www.seagate.com 2.5.4 Extended Po wer Co nditions - Po werChoic e ™ Utilizing the l oad /unload ar chitecture a progr ammable power management interface is pr ovi ded…

100%1 / 49
Seagate IronWolf Pro SATA Product Manual, Rev B 12
www.seagate.com
2.5.1.1 Typical current profiles
Figure 1. DC power requirements (24TB models)
2.5.2 Conducted noise
Noise is specified as a periodic and random distribution of frequencies covering a band from DC to 10 MHz. Maximum
allowed noise values given below are peak-to-peak measurements and apply at the drive power connector.
2.5.3 Voltage tolerance
Voltage tolerance (including noise):
+5v = 250 mV pp from 100 Hz to 20 MHz
+12v =
800 mV pp from 100 Hz to 8 KHz
450 mV pp from 8 KHz to 20 KHz
250 mV pp from 20 KHz to 5 MHz
+5v = ± 5%
+12v = ± 10%
Seagate IronWolf Pro SATA Product Manual, Rev B 13
www.seagate.com
2.5.4 Extended Power Conditions - PowerChoice™
Utilizing the load/unload architecture a programmable power management interface is provided to tailor systems for
reduced power consumption and performance requirements.
The table below lists the supported power conditions available in PowerChoice. Power conditions are ordered from
highest power consumption (and shortest recovery time) to lowest power consumption (and longest recovery time)
as follows: Idle_a power >= Idle_b power >= Idle_c power >= Standby_z power. Note in the table that lower power
states result in greater energy savings. For example, Idle_b results in greater power savings than the Idle_a power
condition. Standby results in the greatest power savings.
Each power condition has a set of current, saved and default settings. Default settings are not modifiable. Default and
saved settings persist across power-on resets. The current settings do not persist across power-on resets. At the time
of manufacture, the default, saved and current settings are in the Power Conditions log match.
PowerChoice is invoked using one of two methods:
Automatic power transitions which are triggered by expiration of individual power condition timers. These timer
values may be customized and enabled using the Extended Power Conditions (EPC) feature set using the
standardized Set Features command interface.
Immediate host commanded power transitions may be initiated using an EPC Set Features "Go to Power
Condition" subcommand to enter any supported power condition. Legacy power commands Standby Immediate
and Idle Immediate also provide a method to directly transition the drive into supported power conditions.
PowerChoice exits power saving states under the following conditions:
Any command which requires the drive to enter the PM0: Active state (media access)
Power-on reset
PowerChoice provides the following reporting methods for tracking purposes:
Check Power Mode Command
Reports the current power state of the drive
Identify Device Command
EPC Feature set supported flag
EPC Feature enabled flag is set if at least one Idle power condition timer is enabled
Power Condition Log reports the following for each power condition:
Nominal recovery time from the power condition to active
If the power condition is Supported, Changeable, and Savable
Default enabled state and timer value
Saved enabled state and timer value
Current enabled state and timer value
Table 7 - Extended power conditions - PowerChoice
Power Condition Name Power Condition ID Description
Idle_a 81H Reduced electronics.
Idle_b 82H Heads unloaded. Disks spinning at full RPM.
Idle_c 83H Heads unloaded. Disks spinning at reduced RPM.
Standby_z 00H Heads unloaded. Motor stopped (disks not spinning).
Seagate IronWolf Pro SATA Product Manual, Rev B 14
www.seagate.com
SMART Read Data Reports
Attribute 192 - Emergency Retract Count
Attribute 193 - Load/Unload Cycle Count
PowerChoice manufacturer default power condition timer values
Default power condition timer values have been established to assure product reliability and data integrity. A
minimum timer value threshold of two minutes ensures the appropriate amount of background drive maintenance
activities occur. Attempting to set a timer value less than the specified minimum timer value threshold will result in an
aborted EPC "Set Power Condition Timer" subcommand.
Setting power condition timer values less than the manufacturer specified defaults or issuing the EPC "Go to Power
Condition" subcommand at a rate exceeding the default timers may limit this products reliability and data integrity.
PowerChoice supported extended power condition feature subcommands
PowerChoice supported extended power condition identifiers
Table 8 - PowerChoice default timer values
Power Condition Name Default Timer Values
Idle_a 100 ms
Idle_b 2 min
Idle_c 10 min
Standby_z 15 min
Table 9 - PowerChoice supported extended condition feature subcommands
EPC Subcommand Description
00H Restore Power Condition Settings
01H Go to Power Condition
02H Set Power Condition Timer
03H Set Power Condition State
04H Enable EPC Feature Set
05H Disable EPC Feature Set
Table 10 - PowerChoice supported extended power condition identifiers
Power Condition Identifiers Power Condition Name
00H Standby_z
01 - 80H Reserved
81H Idle_a
82H Idle_b
83H Idle_c
84 - FEH Reserved
FFH All EPC Power Conditions