28 Supply refi lled If a track h as been deactivated b y a ‘ Track empty ’ error, it can be reactivated by clickin g on the ‘ Sup ply refilled ’ bu tton or sc anning the RETURN b arcode on the track ba rcode bar. ‘ Set-u…

100%1 / 60
27
Component verification with barcode menu
The Component verification with barcode menu cannot be accessed
unless you have configured the Component verification with barcode
option in the machine options and a track barcode has been defined for
the component.
The barcode can be
read off from the reel with the barcode pen or
entered manually via the Manual input button.
a The data for the selected track are displayed here.
s Manual input
You can enter the barcode manually. The barcode you have entered is
compared with the configured data and the result shown in the Barcode
compare window. The result displayed is either same or different.
d Acceptable barcodes
When you click on this button a display box will be displayed which con-
tains a list of (currently) 6 acceptable barcodes.
NOTE
If one position in the barcode is an asterisk (*), this position will not be
included in the barcode comparison.
f Compare barcode
The result of the barcode comparison is either same or different.
g Track
Activate
If a track has been deactivated, it can be reactivated by clicking on the
Activate button or scanning the RETURN barcode on the track barcode
bar.
adfs g
Filter digit
28
Supply refilled
If a track has been deactivated by a Track empty error, it can be
reactivated by clicking on the Supply refilled button or scanning the
RETURN barcode on the track barcode bar.
Set-up check for entire location menu
This menu is used to check the set-up of tracks that are monitored using
barcodes across the entire location. You are prompted to scan the
individual tracks one after another.
a Displays the data for the selected track.
s Manual entry
This option is used to enter the barcode manually. The entered barcode is
compared against the configured data and the result is output in the
Barcode compare window. The result is equal or not equal.
d Acceptable barcodes
Click on this button to call up a display box containing a list of up to 6
barcodes that are currently acceptable.
PLEASE NOTE
If one of the barcode digits is assigned a star (*), this digit will not be
evaluated during the barcode comparison.
f Barcode compare
This box displays the scanned barcode and the result of the barcode
comparison. You are prompted to scan or enter the barcode for each track
one after another. If the scanned barcode does not agree with the desired
barcode, a red bar labeled Not equal appears. Once you have checked
all the tracks, a message box stating Set-up check for entire location
complete appears.
adfsg h
Filter digit
29
g This number indicates how many tracks are left to be checked. The
procedure can be followed on the bar graph.
h Track
Activate
If a track has been deactivated, it can be reactivated by clicking on the
Activate button or scanning the RETURN barcode on the track barcode
bar.
Supply refilled
If a track has been deactivated by a Track empty error, it can be
reactivated by clicking on the Supply refilled button or scanning the
RETURN barcode on the track barcode bar.
Table functions menu
This menu is used to move all the gantries out of the feeder areas in order
to change a feeder or the component feeder table without the risk of a
head crash, for example.
PCB processing must be stopped before this menu can be used.
To do this, click on the Stop processing icon from the main view.
Click on the Set-up icon from the main view.
Click on the Table functions icon.
Click on the All gantries to set-up position button.