48 Fiducial errors This error me ssage wi ll be displayed if it was not possible to fin d or detect a fiducial. Click on OK to ackn owledge and then sele ct from the fun ctions display ed: Abort proces s. PCB With this f…

100%1 / 60
47
Continue processing Refill the components which have run out, set the refilled tracks to Full and
click on Continue processing. Placement will now continue until the board
is finished.
Display errors menu With this menu you can display a list of the errors which have occurred on
the screen.
Feeders menu This menu is used for dealing with empty tracks and track errors.
Single functions Errors caused by the gantry are corrected with the aid of this menu.
Gantry 1 menu
Machine errors
When machine errors occur such as axis errors, for example, the machine
will stop.
Click on OK to acknowledge and then select from the functions displayed:
Abort processing PCB With this function you can abort processing
(see section Abort processing PCB on page 17).
Continue processing With this function you can continue processing.
Display errors menu With this function you can display the machine errors which have occurred
on the screen.
SF Gantries Select this menu to correct the error.
1/2 menu
Transport errors
If boards are not being clamped, placement will be interrupted and the fol-
lowing warning box displayed on the screen:
Click on OK to acknowledge and then select from the functions displayed:
Abort processing PCB With this function you can abort processing PCB
(see section Abort processing PCB on page 17).
Continue processing With this function you can continue processing.
Display errors menu With this function you can display on the screen the transport errors which
have occurred.
SF Transport Select this menu to correct the error.
1/2 menu
48
Fiducial errors
This error message will be displayed if it was not possible to find or detect
a fiducial.
Click on OK to acknowledge and then select from the functions displayed:
Abort process. PCB With this function you can abort processing
(see section Abort processing PCB on page 17).
Continue processing With this function you can continue processing.
Display errors menu With this function you can display the list of the machine errors which have
occurred on the screen.
Single functions Select this menu to correct the error.
Gantry
Resume placement Transport the board onto the output conveyor.
of PCB without Replace the board on the input conveyor.
components loss Transport the board onto the processing conveyor. The board
is stopped there and clamped.
Now select Continue processing.
Nozzle configuration errors
If an error occurs in connection with the nozzle configuration or if the con-
figuration has to be changed, the warning box Nozzle configuration error
Gantry 1/2 will be displayed on the screen.
Abort process Click on the small 'Abort process' box followed by the OK button to abort
the process.
SF Gantries Select the submenu Nozzle configuration revolver head and
1/2 menu change the nozzle.
When you quit the SF menu, a head reference run and a height reference
run with vacuum test will be carried out.
Continue processing With this function you can continue processing.
49
PCB barcode error (option)
If it was not possible to read the barcode properly, the following selection
and dialog box will be displayed on the screen.
enter the correct barcode using the keyboard,
transport the PCB or
remove the PCB from the input conveyor.
Continue processing With this function you can continue processing.
Docking and Undocking the mobile component table
Safety instructions for docking and undocking the mobile component table
WARNING
Never reach into the gap between the component tables and the place-
ment system frame while the machine is running (item 1).
Always check that the component table is docked on the placement sys-
tem before connecting or disconnecting the component table power cable
at the socket on the placement system (item 2).
NEVER connect the component table connecting cable to the socket on
the placement system and then operate the component table via the
external compressed air control unit (item 3).