OM-1076-001.pdf - 第125页

(B02_09) Lead Width Detn/Lead W idth T ol [mm] Select whether or not the Lead Width Judgement is performed. If it is, select the allowance from the following options. Disable : Select this when the lead width determinati…

100%1 / 237
0206-003 2-93 Tg0502-PM-CL
B02 Recognition Data (B02_07), (B02_08)
(B02_07) Mold Size Tolerance Set
Select the component size allowance from the following options.
Manual : Select this to set arbitrary parameters in the "Mold size
tolerance X" and "Mold size tolerance Y" text boxes.
Auto : Select this to automatically set parameters in the "Mold
size tolerance X" and "Mold size tolerance Y" text boxes.
The defaults are automatically set in the "Mold size toler-
ance X" and "Mold size tolerance Y" text boxes.
(a) Set this only when "Manual" is selected in the "Recognition data set"
text box.
(b) Normally, select "AUTO".
When "Auto" is set in the "Mold Size Tolerance Set" text box, the
value indicated in the "Mold Size tolerance" text box is used.
Applicable Components : Cylindrical, Square, and Deform
(Simple)
(B02_08) Mold Size Tolerance X [mm] and Y [mm]
When "Manual" is set in the "Mold Size Tolerance Set" text box, set
the tolerance value for the mold size.
Unit: mm
Data Input Range: 0 to 9.99
(a) When the dimensions described in the component approval drawing
are used for "Mold Size X" and "Mold Size Y", the tolerances might
not become the same (±). In this case, change mold dimensions X
and Y so that both tolerances are increased or decreased to equal
values.
(b) Set parameters only when "Manual" is selected in the "Recognition
data set" and "Mold size tol set" text boxes.
Applicable Components : Cylindrical, Square, and Deform
(Simple)
Fig. B200
Mold size tolerance set
Auto
Fig. B201
Mold size tolerance X [mm]
Mold size tolerance Y [mm]
0.20
0.20
(B02_09) Lead Width Detn/Lead Width Tol [mm]
Select whether or not the Lead Width Judgement is performed. If it is,
select the allowance from the following options.
Disable : Select this when the lead width determination
should not be made.
Enable (Auto) : Select this to automatically set the lead width toler-
ance according to the dimensional data of the leads.
Enable (Mnl) : Select this to arbitrarily set the lead width tolerance.
Unit: mm
Data Input Range: 0 to 9.99
(a) Set this only when "Manual" is set in the "Recognition data set" text
box.
(b) When "Enable (Auto)" is set in the "Lead width detn" text box, the
value indicated in the "Lead width tol [mm]" text box is used.
Applicable Components : IC (Simple), IC (Complex), Other
Leaded (Simple), and Other Leaded
(Complex)
0206-003 2-94
Tg0502-PM-CL
B02 Recognition Data (B02_09)
Fig. B202
Enable (Mnl)
0.30
Lead width detn
Lead width tol [mm]
B02 Recognition Data (B02_10)
0206-003 2-95 Tg0502-PM-CL
Fig. B203
Enable (Auto)
0.00
Lead posn (latl dir) detn
Lead posn (latl dir) tol [mm]
(B02_10) Lead Posn (Latl Dir) Detn/Lead Posn (Latl Dir) Tol [mm]
Select whether or not the Lead Position Judgement to the lead width
direction is performed. If it is, select the allowance from the following
options.
Disable : Select this when the lead position (lateral direc-
tion) should not be detected.
Enable (Auto) : Select this to automatically set the lead position
(lateral direction) tolerance according to the dimen-
sional data of the leads.
Enable (Mnl) : Select this to arbitrarily set the lead position (lat-
eral direction) tolerance.
Unit: mm
Data Input Range: 0 to 9.99
(a) Select this only when "Manual" is set in the "Recognition data set" text
box.
(b) When "Enable (Auto)" is set in the "Lead posn (latl dir) detn" text box,
the value indicated in the "Lead posn (latl dir) tol [mm]" text box is
used.
Applicable Components : IC (Simple), IC (Complex), Connector
(Simple), Connector (Complex), Other
Leaded (Simple), and Other Leaded
(Complex)