TM1609_Explanation to Make the Compatibility between Old 311A-311F Nozzle and New Nozzle.pdf - 第5页
SMT Software Engineeri ng Group IMOperationsYAMAHAMOTORCO. ,LTD. MD OC-SOFT50041 5/10 3.2. Confirmation of Settings Po wer on the m achine, and co nfirm the f ollowing s ettings i n machine set…

SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50041
4/10
When the following screen is displayed in the version up process, please continue the work
with the check mark on “Nozzle Spec Info.”.
As a result, the necessary following informations are reflected in the machine setting to
make the compatibility of 311A/311F nozzle.
[Setting] – [Specification Information] – [Mount Nozzle Specification]
[Setting] – [Specification Information] – [Side View Camera Spec]
* The information set for the special nozzle is not lost, because the information of
Type-31A to Type-31Z for the special nozzle is not overwritten,
* When the information of Type-311 to Type-319 for the standard nozzle have beenn
changed from the initial settings, please make a note of the changed settings, and after
version up is completed, edit it by the machine setting.

SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50041
5/10
3.2. Confirmation of Settings
Power on the machine, and confirm the following settings in machine setting (VmSpec).
1. [Setting] – [Specification Information] – [Mount Nozzle Specification] – [Nozzle Data]
Please confirm the setting of “Nozzle diameter (mm)” for TYPE-311 is “0.8”.
2. [Setting] – [Specification Information] – [Side View Camera Spec] – [Nozzle Basic Setting]
It is not necessary to confirm the setting in the case of the machine that does not equip the
side view camera, the setting item is not displayed.
When “A Nozzle” is selected for Head Type, please confirm the setting of “nozzle tip
width(um)” for TYPE-311 is “730” (which is the size of the new nozzle).

SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50041
6/10
(In the case of YS100) When “F Nozzle” is selected for Head Type, please confirm the setting
of “nozzle tip width(um)” for TYPE-311 is “730” (which is the size of the new nozzle).
* In the machine except for YS100, “0” is set to all the setting values.
When “Compatible Nozzle” is selected for Head Type, please confirm the settings of “nozzle
tip width(um)” for TYPE-311A and TYPE-311F are “350” (which is the size of the old nozzle).
3.3. System Backup
After the work of 3.1 and 3.2, please get the system backup to re-register machine to Y.FacT
P-Tool.