TF36074_Chip Vacuum Check.pdf - 第6页

 2nd SMT En gineer ing Divi sion So ftware Gro u p IM Operations Y AMAHA MOTOR CO., L TD  MD OC-SOFT50395  6/11  Fig 4.2  Part s Adjust screen When p arts adjustment i s executed on the [Parts Adjust] screen opened…

100%1 / 11
2nd SMT Engineering Division Software Group
IM Operations
YAMAHA MOTOR CO., LTD
MDOC-SOFT50395
5/11
3.3 Timing to output errors
Between “after camera recognition of picked parts” and “before mounting”, it monitors
vacuum level for checking of parts existence. The error is not output just after a chip is
dropped off. Timing to display the error is as follows.
When chip is dropped from mounting head
The error message is displayed when XY-axis arrives at the mounting position. At this
time, the error message is displayed for each error head.
When chip is dripped from other than mounting head
The error occurs when mounting of mount head is completed. At this time, the error
message is displayed for each error head.
4. Error Message
When parts fall is detected, the following error message is displayed.
Fig 4.1 Error message dialog
When parts fall is detected, the error message is displayed for each head.
By clicking the [Parts Adj] button on the message, you can see the picking condition and
vacuum level of the error head.
2nd SMT Engineering Division Software Group
IM Operations
YAMAHA MOTOR CO., LTD
MDOC-SOFT50395
6/11
Fig 4.2 Parts Adjust screen
When parts adjustment is executed on the [Parts Adjust] screen opened from the Ea13143
message, it is not allowed to edit the parts data on the right. Also, parts data is not updated
by Test. (
)
Parts Adjust screen opened from the Ea13143 message is used only for confirmation.
() When “Test” is executed on the [Parts] - [Parts Adj] screen, [Comp. Intensity] in parts data is
automatically updated. Meanwhile, when it is executed on the [Parts Adj] screen opened from the Ea13143
message, [Comp. Intensity] is not updated.
5. Recovery from error
When “Ea13143: PARTS DROP BEFORE MOUNT” occurs, press the [Parts Adj] button on
the message, and execute “Test” to check the picking condition of the error nozzle. If no chip
is on the nozzle, it may have been dropped on a board. In that case, please remove it. Then
close the error message and press the [START] button. All error heads perform dumping
action and auto-running starts.
2nd SMT Engineering Division Software Group
IM Operations
YAMAHA MOTOR CO., LTD
MDOC-SOFT50395
7/11
6. Setting Method
Set
tings to use this function are as follows.
Table 6.1 Machine Setting
Menu Description
Set [Chip Vacuum Check] to “Use”.
Enter a value in [Parts Fall Vacuum Level] of each nozzle.
The range is 0 to 255.
When “0” is entered, Chip Vacuum Check is not performed.
(Recommended value is 12) 1