0305-001 2-130 Tg0859-PM-ER Error Code Display A Display B 3. T rouble Shooting after Error Display 69 02 05 NOZZLE STORE NOZZLE STOCKER A2 NOT CLOSED COMPLETEL Y WITHIN SPECIFIED TIME. (Cause 1) This is the device’ s se…

0305-001 2-129 Tg0859-PM-ER
Error Code Display A Display B
3. Trouble Shooting after Error Display
69 02 01 NOZZLE STORE NOZZLE STOCKER A1 NOT OPENED COMPLETELY
WITHIN SPECIFIED TIME.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
69 01 0B NOZZLE ATTACH NOZZLE STOCKER B2 NOT CLOSED COMPLETELY
WITHIN SPECIFIED TIME.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
69 01 0A NOZZLE ATTACH NOZZLE STOCKER B2 NOT OPENED COMPLETELY
WITHIN SPECIFIED TIME.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
69 01 09 NOZZLE ATTACH NOZZLE STOCKER B1 NOT CLOSED COMPLETELY
WITHIN SPECIFIED TIME.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.

0305-001 2-130 Tg0859-PM-ER
Error Code Display A Display B
3. Trouble Shooting after Error Display
69 02 05 NOZZLE STORE NOZZLE STOCKER A2 NOT CLOSED COMPLETELY
WITHIN SPECIFIED TIME.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
69 02 04 NOZZLE STORE NOZZLE STOCKER A1 NOT CLOSED COMPLETELY
WITHIN SPECIFIED TIME.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
69 02 03 NOZZLE STORE NOZZLE STOCKER B1 NOT OPENED COMPLETELY
WITHIN SPECIFIED TIME.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
69 02 02 NOZZLE STORE NOZZLE STOCKER A2 NOT OPENED COMPLETELY
WITHIN SPECIFIED TIME.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.

0305-001 2-131 Tg0859-PM-ER
3. Trouble Shooting after Error Display
Error Code Display A Display B
69 02 0A NOZZLE STORE
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can't be re-started, contact our service personnel.
69 02 09 NOZZLE STORE NOZZLE STOCKER B2 NOT CLOSED COMPLETELY
WITHIN SPECIFIED TIME.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
69 02 08 NOZZLE STORE NOZZLE STOCKER B2 NOT OPENED COMPLETELY
WITHIN SPECIFIED TIME.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
69 02 07 NOZZLE STORE NOZZLE NOT STORED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
69 02 06 NOZZLE STORE NOZZLE STOCKER B1 NOT CLOSED COMPLETELY
WITHIN SPECIFIED TIME.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.